Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Permit: DP21-0313

Parcel: 13819039C


Addresses:

402 W MEDINA RD

Inspection Status: Not Ready

Inspection History

Date Description Inspector Results Comments
07/22/2024 Not Ready Not ready due to rain preventing them from tieing rebar properly.
07/23/2024 Passed On the west side about half way down the footing there was a small amount of dirt under the bottom rows of rebar, insure this is cleaned out prior to pouring.
08/01/2024 Partial Pass Retaining wall mid inspection prior to grout, water proof and backfill, at 5 rows of 8.
08/05/2024 Partial Pass Wall has been partially grouted so backfill can start. Rest of the wall will be called in at a later time and inspections will proceed on those two sections.
08/09/2024 Not Ready Due to the rains, the contractor will have to clean the trenches up and have them ready by first part of next week and will recall this inspection in and have it redone
08/14/2024 Partial Pass Ready to pour/grout
08/30/2024 Passed