Inspection Status: Not Ready
Inspection History: ENGR Engineering Final
| Date |
Description |
Inspector |
Results |
Comments |
| 10/27/2022 |
ENGR Engineering Final
|
|
Not Ready |
|
| 10/27/2022 |
ENGR Engineering Final
|
|
Not Ready |
|
| 01/27/2023 |
ENGR Engineering Final
|
|
Complete (Recurring) |
Complete this site as shown on the approved plans for the development package. The engineer of record needs to provide detail drawings I will be cross-sections for all daily status throughout the site. These details will need to reflect the rock riprap that is shown on the plans and how it is to be installed on the site does it include rock rack and filter fabric or just rock riprap by itself. Install the drill down hose for the trash enclosure doors in the open and close positions as per the details in our standards.Complete all franchise there’s a showing on the side on the approved plans. |
| 01/27/2023 |
ENGR Engineering Final
|
|
Complete (Recurring) |
Complete this site as shown on the approved plans for the development package. The engineer of record needs to provide detail drawings I will be cross-sections for all daily status throughout the site. These details will need to reflect the rock riprap that is shown on the plans and how it is to be installed on the site does it include rock rack and filter fabric or just rock riprap by itself. Install the drill down hose for the trash enclosure doors in the open and close positions as per the details in our standards.Complete all franchise there’s a showing on the side on the approved plans. |
| 03/10/2023 |
ENGR Engineering Final
|
|
Passed |
|
| 03/10/2023 |
ENGR Engineering Final
|
|
Passed |
|