Permit: DP17-0153

Parcel: Unknown


Addresses:

9070 E OLD VAIL RD

Inspection Status: Passed

Inspection History: ENGR Grading Final

Date Description Inspector Results Comments
05/18/2018 ENGR Grading Final MRUSSO Approved Entered by DROBERT5 -
02/08/2018 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - 1) CIVIL PLANS SHOW INSTALL OF PRE-FAB METAL BLDGS ON A CONCRETE PAD, NO DETAIL PROVIDED. 2) CONTRACTOR PROVIDED A STRUCTUAL PLAN (TLCP STRUCTUAL ENGINEERING) FOR CONSTRUCTION OF THE BLDG PADS, HOWEVER THERE ARE NO COT STAMPS 3) INSTALLATION INCLUDED WIRE MESH WITH THREE #4 BARS HORIZONTAL ALONG BOTH SIDES OF THE PAD. FOOTINGS OR TOE DOWN IS 18"W BY 16" D. 4) PROVIDE EOR APPROVAL FOR METAL BLDG PAD CONSTRUCTION AND COT APPROVAL FOR RE-ENFORCEMENT INSTALLATION. 5) BULDINGS MAY REQUIRE A SEPARTE BLDG PERMIT.
01/23/2018 ENGR Grading Final DROBERT5 Continued Entered by DROBERT5 - THE LANDSCAPERS HAVE TRENCHED FOR THE POLY INSTALLATION ALONG THE EAST AND SOUTH SIDES OF THIS SITE AND WILL BE INSTALLING THE CONTROLER LINES AND PLACING BACKFILL IN THE LOWER PORTION OF THE TRENCHES. ONCE THIS HAS BEEN COMPLETED THEY WILL BE INSTALLING ADDITIONAL PIPES AND SENSOR WIRES AND BACKFILL. I HAVE REMINDED THEM THAT THEY WILL NEED TO ALSO INSTALL THE INDICATOR TAPE WITHIN THE TOP 6 INCHES OF THE TRENCH BACKFILL.
06/22/2018 ENGR Grading Final RLEDONNE Approved Entered by RLEDONN1 -
06/22/2018 ENGR Grading Final RLEDONNE Approved Entered by RLEDONN1 -
06/22/2018 ENGR Grading Final RLEDONNE Approved Entered by RLEDONN1 -
03/28/2018 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - PROGRESS INSPECTION, NO SITE CHANGES OR CONCERNS AT THIS TIME
02/08/2018 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - 1) CIVIL PLANS SHOW INSTALL OF PRE-FAB METAL BLDGS ON A CONCRETE PAD, NO DETAIL PROVIDED. 2) CONTRACTOR PROVIDED A STRUCTUAL PLAN (TLCP STRUCTUAL ENGINEERING) FOR CONSTRUCTION OF THE BLDG PADS, HOWEVER THERE ARE NO COT STAMPS 3) INSTALLATION INCLUDED WIRE MESH WITH THREE #4 BARS HORIZONTAL ALONG BOTH SIDES OF THE PAD. FOOTINGS OR TOE DOWN IS 18"W BY 16" D. 4) PROVIDE EOR APPROVAL FOR METAL BLDG PAD CONSTRUCTION AND COT APPROVAL FOR RE-ENFORCEMENT INSTALLATION. 5) BULDINGS MAY REQUIRE A SEPARTE BLDG PERMIT.
01/23/2018 ENGR Grading Final DROBERT5 Continued Entered by DROBERT5 - THE CREWS ARE WORKING ON THE FOLLOWING ITEMS: 1) INSTALLING LANDSCAPING, POLY TUBING 2) INSTALLING CHAIN LINK FENCE ALONG THE PERIMETER. 3) GRADING FOR ADDITIONAL PAVEMENT