Inspection Status: Passed
Inspection History: ENGR Grading Final
| Date |
Description |
Inspector |
Results |
Comments |
| 05/04/2017 |
ENGR Grading Final |
MRUSSO |
Approved |
Entered by DROBERT5 - |
| 05/18/2017 |
ENGR Grading Final |
DROBERTS |
Approved |
Entered by DROBERT5 - |
| 05/18/2017 |
ENGR Grading Final |
DROBERTS |
Approved |
Entered by DROBERT5 - |
| 03/29/2017 |
ENGR Grading Final |
MRUSSO |
Continued |
Entered by DROBERT5 - NO SITE/GRADING CONCERNS AT THIS TIME |
| 01/11/2017 |
ENGR Grading Final |
MRUSSO |
Continued |
Entered by DROBERT5 - CONTRACTOR WORKING ON BLDG, NO SITE WORK AT THIS TIME |
| 11/17/2016 |
ENGR Grading Final |
MRUSSO |
Continued |
Entered by MRUSSO1 - 1) TRANSITION FROM RCP TO SRP , INSTALLED PER PLAN
2) PICTURES TAKEN OF INSTALL AND RE-ENFORCEMENT |
| 11/09/2016 |
ENGR Grading Final |
MRUSSO |
Continued |
Entered by MRUSSO1 - 1) LOOK AT 48" SRP STORM PIPE INSTALLED PER APPROVED PLANS. PIPE WAS BEDDED TO THE SPRING LINE - OK TO COVER
2) CALL FOR INSPECTION PRIO TO COVERING TRANSITION FROM RCP TO SRP AND MANHOLE CONSTRUCTION |
| 05/18/2017 |
ENGR Grading Final |
DROBERTS |
Approved |
Entered by DROBERT5 - |
| 05/19/2017 |
ENGR Grading Final |
DROBERTS |
Approved |
Entered by DROBERT5 - |
| 04/13/2017 |
ENGR Grading Final |
MRUSSO |
Partial Approval |
Entered by DROBERT5 - RE-BAR LAY OUT FOR TRASH ENCLOSURE APRONS INSTALLED PER THE CITY OF TUCSON DEV STD 6-01.0 - OK TO POUR CONCRETE |
| 03/16/2017 |
ENGR Grading Final |
MRUSSO |
Partial Approval |
Entered by DROBERT5 - RE-BAR FOR TRASH ENCLOSURE CORRECTED
SUPPLEMENTAL RE-BAR INSTALLED - OK TO COVER |
| 03/09/2017 |
ENGR Grading Final |
MRUSSO |
Denied |
Entered by DROBERT5 - TRASH ENCLOSURE @ SE CORNER OF BLDG DOES NOT MEET THE COT STD 6-01.0 FOR STRUCTURAL DESIGN.
PROVIDE FOOTINGS AND RE-BAR PER THE ABOVE LISTED COT DETAIL |