Permit: DP16-0035

Parcel: 13609024U

Inspection Status: Not Ready

Inspection History: ENGR Engineering Final

Date Description Inspector Results Comments
10/27/2022 ENGR Engineering Final Not Ready
10/27/2022 ENGR Engineering Final Not Ready
02/22/2021 ENGR Engineering Final MHERNADEZ Not ready for Inspection Entered by RSALDAT1 - NR 9180 (LANDSCAPE INSPECTION) construction must leave a phone number .so we can inspect .9185 and 9190.
12/13/2017 ENGR Engineering Final RLEDONNE Not ready for Inspection Entered by RLEDONN1 - COMPLET ALL NOTES FROM 11-16-2017 & 8-15-2017.
11/16/2017 ENGR Engineering Final RLEDONNE Not ready for Inspection Entered by RLEDONN1 - CLEAN ALL DRIT AND TRASH FROM ALL RIP-RAP. STAKE TREES PER DETAIL 1 ON PAGE L1. COMPLET ALL SIDE WALKS AND REPAIR SIDE WALKS NORTH OF MODEL PARKING AREA SLOPES ARE OVER2%.
09/08/2017 ENGR Engineering Final RLEDONNE Not ready for Inspection Entered by RLEDONN1 - MET WITH CONCRETE WORKERS AT SIDEWALKS ON WEST SIDE OF SITE.
08/15/2017 ENGR Engineering Final RLEDONNE Not ready for Inspection Entered by RLEDONN1 - CLEAN SEDIMENT FROM BASIN AND CATCH BASIN IN STREET REPAIR AND ADD SWPPP CONTOLS. RAMP LANDINGS AND SIDEWALKS OVER 2% ALL SIDEWALKS NEED TO BE COMPLETED PER AP PLANS. INSTALL RIP-RAP PER DETAIL F ON PAGE C6 3:1TO2:1.EROSION ON ALL SIDES 0F SITE. ADD FILTER FABRIC AND RIP-RAP TO WALL OPENINGS PER DETAIL0N PAGE #6. PROVIDE AS-BUILTS AND CERT LETTER FROM ENGRINEER OF RECORD FOR ALL GRADING AND DRAINAGE.
08/14/2017 ENGR Engineering Final RLEDONNE Not ready for Inspection Entered by RLEDONN1 - WALKED PART OF THE SITE WITH DAVE TODAY. WALK OTHER HALF TOMORROW.
07/21/2017 ENGR Engineering Final DROBERTS Correction Required Entered by DROBERT5 - MET WITH CLAYTON AND DISCUSSED THE SLOPES OF THE SIDEWALK AND THE DRIVEWAY INTO THE MODEL HOME. THE CURRENT CONDITIONS OF THE SITE IS NOT ACCEPTABLE FOR THE MODEL HOME AND THE DEVELOPER WITH HAVE TO COME UP WITH AN ALTERNATE SOLUTION FOR THE ADA ACCESSIBLE PATH FROM THE PARKING LOCATIO0N INTO THE MODEL HOME SITE. I INFORMED THE DEVELOPER OF THE REQUIREMENTS AND THEY WILL WORK ON AN ALTERNATE PATHWAY OR PARKING LOCATION.
07/20/2017 ENGR Engineering Final DROBERTS Not ready for Inspection Entered by DROBERT5 - MET ON SITE WITH THE DEVELOPER AND LOOKED OVER THE AREAS THAT HE IS LOOKING FOR APPROVAL OF THE SIDEWALK ON THIS SITE. THE ADA PARKING SPACES AND ACCESS AISLE FOR THE MODEL HOME IS LESS THAN THE 2% SLOPES IN ALL DIRECTIONS. THE SIDEWALK FROM THE ADA PARKING AREA TO THE ADJACENT SIDEWALK IS OK FOR CROSS SLOPES BUT THE RUNNING SLOPE IS 6.5% TO 7.5% WHICH WILL REQUIRE THAT A HANDRAIL BE PLACED ON BOTH SIDES OF THE SIDEWALKS. THE DRIVE ENTRANCE INTO THE MODEL HOME IS AT 15% OR GREATER IN AREAS, I WILL CHECK WITH CLAYTON ON THIS TO SEE WHAT IF ANYTHING IS ACCEPTABLE.
09/27/2023 ENGR Engineering Final Passed
09/27/2023 ENGR Engineering Final Passed