Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Inspection History Details
Inspection Status: Passed
Inspection History: ENGR Engineering Final
Permit Number - DP15-0191
Inspection Description - ENGR Engineering Final
Inspection Status - Passed
Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/29/2020 | ENGR Engineering Final | DROBERTS | Approved | Entered by DROBERT5 - |
11/26/2019 | ENGR Engineering Final | DROBERTS | Not ready for Inspection | Entered by DROBERT5 - tHIS SIT HAS BEEN INSPECTED ON THIS DATE AND THE FOLLOWING HAS BEEN NOTED DURING THIS INSPECTION: 1) REMOVE ALL OF THE STORMWATER CONTROLS PRIOR TO REQUESTING THE FINAL INSPECTION AND RELEASE FOR THIS SITE. 2) PROVIDE ANY REVISED DRAWINGS IF THERE HAS BEEN ANY CHANGES, AND PROVIDE THIS DEPARTMENT WITH A CERTIFICATION LETTER FROM THE ENGINEER OF RECORD FOR THIS PROJECT. 3) COMPLETE ALL WORK ON THIS SITE AS SHOWN ON THE APPROVED ON THIS PLANS, AND PROVIDE REVISED DOCUMENTATION IF NEEDED. 4) COMPLETE THE WORK ON THIS SITE TILL THERE IS LESS THAN ONE OPEN ACRE OF DISTURBED, THIS WILL ALLOW THE CLOSURE OF THE SWPPP PERMIT, AND PROVIDE THIS DEPARTMENT A COPY OF THE NOTICE OF TERMINATION APPROVAL FOR THIS SITE. 5) COMPLETE CONSTRUCTION ON ALL OF THE REMAINING OPEN LOTS THAT HAVE NOT BEEN COMPLETED AS FOLLOWS: UNDER CONSTRUCTION: LOTS 34, 16, 17, 18, 61, 41, NOT DEVELOPED: LOTS 29, 30, 31, 32, 33, 35, 60, 59, 58, 42, 44, |