Permit: DP13-0217

Parcel: Unknown

Inspection Status: Passed

Inspection History: ENGR Grading Final

Date Description Inspector Results Comments
01/08/2015 ENGR Grading Final MRUSSO Approved Entered by DROBERT5 -
01/06/2015 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - 1) CONTRACTOR PAVED SITE, 2) LANDSCAPE MOSTLY COMPLETE 3) COMPLETE STRIPING AND INSTALL HC PARKING
12/17/2014 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - CONTRACTOR PREPING FOR PAVING, HOWEVER RAIN IS FORCAST FOR THE NEXT DAY.
12/15/2014 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - PAVING NEXT WEEK, SUBGRADE SET
11/19/2014 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - NO SITE/GRADING CONCERNS AT THIS TIME
11/13/2014 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - 1) PAVING SOON CALL FOR INSPECTION AT SUBGRADE 2) BUBBLERS WILL BE INSTALLED AT TWO ROOF DRAINS 3) NO SWPPP, HOWEVER ENSURE TRACKING ON PUBLIC ROADWAY IS SWEEPED UP
10/29/2014 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - 1) WALKED SITE 2) SOME CHANGES TO SIDEWALK SCUPPERS 3) ANY SIGNIFCANT CHANGES TO THE APPROVED SITE/GRADING PLAN MUST BE REVISED AND APPROVED. 4) PROVIDE A CERT STATEMENTAND AS-BUILT FROM THE EOR PRIOR TO FINAL.
10/09/2014 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - NO CHANGES AND/OR COCNERNS AT THIS TIME
10/06/2014 ENGR Grading Final DROBERTS Continued Entered by DROBERT5 - MET WITH THE CONTRACTOR ONSITE AND LOOKED OVER THE HANDICAP ACCESS RAMP THAT IS LOCATED ON THE NORTH SIDE OF THE BUILDING. THIS RAMP EXCEEDS THE 5% SLOPE GRADE FOR THE RAMP AND RISES MORE THAN SIX INCHES SO IT WILL REQUIRE A CONTINOUS HANDRAIL ON BOTH SIDES OF THE RAMP. MET WITH RON BROWN AND VERIFIED THE HANDRAIL WHEN I RETURNED DOWNTOWN, ADVISED THE CONTR4ACTOR OF THE SAME.
09/04/2014 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - 1) NO SIGNIFICANT STORM WATER COCNERNS AT THIS TIME. 2) INSPECTED RE-BAR LAY OUT FOR PERIMETER WALL FOOTINGS/INSTALLED PER PLAN #5 @ 32" OC PICTURES TAKEN.
01/08/2015 ENGR Grading Final MRUSSO Approved Entered by DROBERT5 -
11/13/2014 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - RE-BAR LAY OUT FOR TRASH ENCLOSURE FOOTING AT NE CORNER OF SITE. NO INSPECTION CALLED IN
09/04/2014 ENGR Grading Final MRUSSO Continued Entered by DROBERT5 - INSPECTED RE-BAR LAY OUT FOR PERIMETER WALL FOOTINGS/INSTALLED PER PLAN #5 @ 32" OC PICTURES TAKEN.
09/03/2014 ENGR Grading Final IVR USER Cancelled Entered by IVR USER - IVRS - RI canceled
02/02/2015 ENGR Grading Final MRUSSO Approved Entered by DROBERT5 -
02/02/2015 ENGR Grading Final MRUSSO Approved Entered by DROBERT5 -