Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO.
If you cannot find what you are looking for please
submit a records request.
Inspection Status: In Violation
Inspection History: COT - ENFC - Code Enforcement - Follow Up
| Date |
Description |
Inspector |
Results |
Comments |
| 01/30/2023 |
COT - ENFC - Code Enforcement - Follow Up |
|
In Violation |
ON SITE WITH INSPECTOR GONAZALEZ. SPOKE WITH PATRICIA ASHWORTH WHOM STATED THAT WARREN WAS CURRENTLY OUT OF THE UNIT. SHE SAID THAT TC3 WAS GOING TO START ROOF REPAIRS ON THE DWELLING TODAY. INSPECTOR GONZALEZ SENT AN EMAIL TO FIRE TC3 TO CONFIRM. NO ONE HAS CONFIRMED. THE REFUSE AND DEBRIS AND JMV REMAIN. THERE ARE NOW NEW VIOLATIONS WITH A RV IN THE RIGHT OF WAY. NEIGHBORS CALLED CSR'S LATER IN THE DAY TO SAY THAT THEY WERE RUNNING POWER FROM THE DWELLING TO THE RV. PATRICIA HAD SAID THAT SHE DID NOT KNOW WHOM THE RV BELONGED TO. SENDING CITATIONS TO JUSTIN ASHWORTH, PATRICIA ASHWORTH AND WARREN SCHAFFER. |
| 02/27/2023 |
COT - ENFC - Code Enforcement - Follow Up |
|
In Violation |
ON SITE WITH JENNIFER ANGLADA SPOKE TO HER ABOUT VIOLATIONS AND THAT I WAS GETTING A WARRANT TO ENTER THE PROPERTY AND CONDEMN |
| 03/01/2023 |
COT - ENFC - Code Enforcement - Follow Up |
|
In Violation |
ON SITE WITH SUPERVISOR GONZALEZ, TPD, TC-3, BOARD UP AND OCCUPANTS. AN ADMINISTRATIVE SEARCH WARRANT WAS SERVED TO ENTER THE DWELLING. THE DWELLING WAS FOUND TO BE UNSAFE AND DETERIORATING. THE 1ST BEDROOMS CEILING HAD COLLAPSED AND DAY LIGHT WAS VISIBLE FROM THE ROOF. THE ROOF BEAMS WERE EXPOSED. THE SECOND BEDROOM HAD AN ESTIMATED 4X4 HOLE IN THE CEILING. THERE WERE MULTIPLE ELECTRICAL DEVICES THAT HAD EVIDENCE OF PREVIOUS BURNS AND OR WERE MISSING COVER PLATES. THERE WERE MULTIPLE EXSTENSION CORDS BEING USED UNSAFELY THROUGHOUT THE UNIT. SOME OF THE CORDS WERE SPLICED AND HOT WIRES WERE EXPOSED. THE FLOORS SHOWED EVIDENCE OF RODENT INFESTATION THROUGHOUT THE DWELLING. THERE WAS ONE BATHROOM TO THE DWELLING THAT WAS NO LONGER ABLE TO BE USED DUE TO PLUMBING ISSUES. THE TOILET WAS NOT USEABLE. THE BATHROOM SINK WAS NOT DRAINING AND HAD STAGNANT WATER IN THE SINK. THE SHOWER DID NOT DRAIN OR HAVE ANY EQUIPMENT PRESENT TO TURN THE WATER ON. THE PROPERTY HAD MULTIPLE STOLEN VEHICLES IN THE YARD AND STOLEN CAR PARTS. THERE WAS REFUSE AND DEBRIS THROUGHOUT THE PROPERTY INCLUDING ADDRESS 1207 AND 1215 E 36TH. THERE WAS A WOOD FENCE THAT HAD BEEN PUT UP WITHOUT A COMPLIANCE REVIEW. ELECTRICAL CORDS WERE BEING RAN FROM INSIDE THE DWELLING TO 2 DIFFERENT CAMPERS. THERE WERE PEOPLE LIVING IN THE CAMPERS ON THE PROPERTY OF 1207 AND 1215. |
| 04/24/2023 |
COT - ENFC - Code Enforcement - Follow Up |
|
Completed |