Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

Closed - Resolved

Type:

EMERGENCY CALL: TPD/TFD
Address:

Entered Date:

08/26/2022

Applicant:

N/A

Description:

Completed Inspections

Case Status: Closed - Resolved
Case Number: T22DV04997
Case Description: EMERGENCY CALL: TPD/TFD
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/26/2022 COT - ENFC - Code Enforcement - Initial Passed {Activity date: 08/26/2022; Status: Approved; Inspector: VIDAL; Comment: Entered by VIDAL - T.P.D. has been on the property and observed issues that need to be checked. Did meet with the owner of the business and did an inspection with his approval. The owner was with us as doing the inspection and answered all questioned when asked about issues or where something was. The C of O was lacking when checking permits plus and has one posted and being checked with permits plus. Has a opening cut into the wall to enter the unit next door and are combined as one buisness.The area is being used as a dance floor. Again no permit found for the opening cut into the wall. Has a DJ booth and has a hookah and the wooden floor has burning where has no protection for opened sparks going onto the floor from the hookah when being used in the DJ booth. Lacking GFCI outlets in the bathrooms and has outlets in the lights in the bathrooms and not GFCI protected. Has no bathroom for the Handi-cap due to lacking grab bars at the toilet area. The main electrical panels are not labeled property, has the rear doors blocked with a accordian panels and the doors are lacking panic devises. Has a electrical box added in the front and not supported properly, has a electric water heater and has items stored against the water heater, Has ceiling tiles that are broken or missing on the drop ceiling. The room where the water heater is located was for washer and dryer and has been converted to a room for prepping the hookahs. The door in the 3728 at the front is locked and have to open the locks to exit. Exit signs are missing and have outlets that are lacking cover plates or are broken. The C of O appears to have been made and not matching the C of O that the City of Tucson issues. The permit number comes to another address for solar panels in 2015. Tucson Fire Inspector was on site and also did an inspection. One of the rear doors is bolted shut and has angle iron holding the door closed. Did let the owner of the buisness know that a permit is required for the C of O and will need a floor plan on what the layout of the buisness as is at this time. Did go over the opening in the wall that was cut may have been a fire wall and that will need to be check when getting the permit. The owner did sign the paperwork and given the copies. The paperwork was done in the owner of the property name and will be doing a N.O.V. and mailed to the owner who lives out of state. The business was secured when leaving the site by the owner. Did do the posting on the front door areas on both units. RV.} ; {Activity date: 08/26/2022; Status: Approved; Inspector: BIGMAN; Comment: Entered by BIGMAN - FALSE C OF O POSTED ON WALL OF BUSINESS, NO GFCI IN BATHRMS, FLOOR PLAN CHANGED W/OUT PERMIT, EXTENSION CORDS BEING USED AS LONG TERM ELECTRICAL, NO COVER PLATES, COMBUSITBLE STORAGE AGAINST WATER HEATER}
08/25/2023 COT - ENFC - Code Enforcement - Follow Up Passed This business never came back and the owner of the business not able to make contact with. The owner of the property has no lease with that person anymore. There is a demo permit where the work that required a permit is being removed by a contractor. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Case Activity

Case Number - T22DV04997
Case Status: Closed - Resolved
Case Description: EMERGENCY CALL: TPD/TFD
Description Date Status
CONTACTED BY MAILING 08/26/2022 Passed
NOTICE OF VIOLATION ISSUED 08/26/2022 Passed
STRUCTURE SECURED BY ??? 08/26/2022 Passed