Case: T22DV03997
Case Details
Status:
Closed - Resolved
Type:
Building #7 , second floor balcony for this building is dilapidated. 2x4 support beams have started to pull away from wall, 2x6 being walked on is rotting. dangerous structural issues. staircase railing is twisted middle portion
Address:
Entered Date:
07/14/2022
Applicant:
N/A
Description:
Case Violations
Case Number: T22DV03997
Case Status: Closed - Resolved
Case Description: Building #7 , second floor balcony for this building is dilapidated. 2x4 support beams have started to pull away from wall, 2x6 being walked on is rotting. dangerous structural issues. staircase railing is twisted middle portion
Total Violations: 2
Violation Date | Code Statue |
---|---|
07/27/2022 | T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition. |
07/27/2022 | T.C. Ch. 16, Sec. 16-12(a)(2) EXTERIOR SURFACES, PROTECTIVE TREATMENT All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
Completed Inspections
Case Status: Closed - Resolved
Case Number: T22DV03997
Case Description: Building #7 , second floor balcony for this building is dilapidated. 2x4 support beams have started to pull away from wall, 2x6 being walked on is rotting. dangerous structural issues. staircase railing is twisted middle portion
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/26/2022 | COT - ENFC - Code Enforcement - Initial | Passed | {Activity date: 07/26/2022; Status: Approved; Inspector: MORALES; Comment: Entered by MORALES - ON SITE WITH MANAGER AND INSECTOR RV. THE UPPER DECK AREA IN BUILDING 7 BEWTEEN UNITS 720 AND 718 NEEEDS SOME REPAIR WORK.} | |
09/29/2022 | COT - ENFC - Code Enforcement - Follow Up | Passed | {Activity date: 09/29/2022; Status: Approved; Inspector: MORALES; Comment: Entered by MORALES - ON SITE WITH MANAGER. THE UPPER DECK HAS BEEN REPAIRED. CLOSE CASE.} |
Completed Case Activity
Case Number - T22DV03997
Case Status: Closed - Resolved
Case Description: Building #7 , second floor balcony for this building is dilapidated. 2x4 support beams have started to pull away from wall, 2x6 being walked on is rotting. dangerous structural issues. staircase railing is twisted middle portion
Description | Date | Status |
CONTACTED BY PHONE | 07/22/2022 | Passed |
CONTACTED BY MAILING | 07/27/2022 | Passed |
NOTICE OF VIOLATION ISSUED | 07/27/2022 | Passed |
VIOLATION CLOSED | 09/29/2022 | Passed |