Case: T22DV03143
Case Details
Entered Date:
05/26/2022
Applicant:
NOTTINGHILL GATE TUCSON LLC
Description:
APARTMENT FIRE
Outstanding Inspections
Case Number: T22DV03143
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T22DV03143
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
05/26/2022 | INSP - INITIAL CODE ENFORCMENT | TIDWELL | Approved | : EMERGENCY CALL OUT BY TFD: THERE IS FIRE DAMAGE TO THE INTERIOR OF THE UNIT, ALL SHEETROCK HAS BEEN DESTROYED BY FIRE AND WATER. THERE ARE SURFACE BURNS ON MULTIPLE TRUSSES, THE TOP PLATE'S TO THE FRONT AND ABUTTING UNITS HAVE SURFACE BURNS WITH DEEP CRACKS. THERE IS A ROOF CUT OUT 4 X 6 . THE BUILDINGS CANTILEVERED OVERHANG IS ESTIMATED BY 5 FEET BY 40 FEET, THIS AREA HAS SHEETROCK DAMAGED. THE FRONT DOOR AND WINDOW ARE DESTROYED. THE BUILDINGS BLOCK IS DISCOLORED. ELECTRICAL: ALL ELECTRICAL DEVICES ARE MELTED, BURNT WITH BARE WIRING. UNABLE TO DISCONNECT POWER, THE PANEL BOARD LOCATED IN THE COURT YARD DID NOT HAVE ANY CIRCUITS FOR THE SOUTH BUILDING IDENTIFIED AS BUILDING B. THIS PANEL ALSO HAS BROKEN BREAKERS AND IS NOT CODE COMPLIANT. TFD AND TEP COULD NOT ASSIST. PLUMBING: GAS IS MASTER METERED AND WAS SHUT OFF, THE LACK OF GAS IMPACTS NO RANGE USE. MECHANICAL: HEAVY SMOKE REMARKS: PERMIT REQUIRED FOR REPAIRS, THE APARTMENT WAS CONDEMNED, UNFIT TO OCCUPY. UNABLE TO CONTACT MANAGEMENT AND EMERGENCY PHONE NUMBER FOR MAINTENANCE WAS INOPERABLE. POSTED NOTICE AT MANAGERS OFFICE OTHER EFFECTED UNIT ARE AS FOLLOWS: B-134 WATER INTRUSION / POWER SHUT OFF AT SUB PANEL B-135 WATER INTRUSION / POWER SHUT OFF AT SUB PANEL B-236 WATER INTRUSION / POWER SHUT OFF AT SUB PANEL B-234 WATER INTRUSION / POWER SHUT OFF AT SUB PANEL INSPECTOR: BETH TIDWELL DATE 05-26-2022 |
05/29/2022 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | DOCS IN ONBASE CLOSE CASE |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T22DV03143
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date | Name |
05/29/2022 | CONTACTED BY PHONE |
05/26/2022 | CONTACTED IN PERSON |
05/26/2022 | NOTICE AND ORDER ISSUED |
05/26/2022 | VIOLATION CLOSED |
05/26/2022 | STRUCTURE SECURED BY ??? |
05/26/2022 | CALLBACK |