Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T22DV01910
Case Details
Entered Date:
03/18/2022
Applicant:
MANTEL PROPERTIES LLC
Description:
STRUCTUAL DAMAGE TO THE WALKWAY
Completed Inspections
Case Status: COMPLIAN
Case Number: T22DV01910
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/18/2022 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CALL OUT BY TFD: THERE IS DAMAGE DUE TO WOOD ROT AND FIRE TO THE WALKWAY'S SUPPORT WOOD MEMBERS, THE WALKWAY IS A CONCRETE CAP ON TOP OF A WOOD DECK AND FRAMING MEMBERS. THE CONCRETE STAIRS ARE SUPPORT BY A STEEL FRAME FROM THE FIRST FLOOR TO THE SECOND FLOOR AND BOLTED TO THE WOOD FRAMING MEMBERS ON THE SECOND FLOOR. THE WOOD SUPPORT MEMBER WHERE THE STAIR FRAME BOLTS TO HAS SPLIT AND HAS LOOSE BOLTS. THE WOOD MEMBERS UNDERNEATH THE FRAME HAS SEVERE WOOD ROT AND FIRE DAMAGE. REMARKS: A STRUCTURAL ENGINEERING AND A PERMIT IS REQUIRED FOR REPAIRS. THE CONCRETE STAIRS TO THE THE SECOND FLOOR WALKWAY AND THE END OF THE WALKWAY WAS BARRICADED. A 4 X 4 VERTICAL SUPPORT WAS INSTALLED TO SUPPORT THE WALKWAY'S DEAD LOAD. UNITS 210, 211 AND 212 WERE CONDEMNED DUE TO THE LOCATION OF THE UNITS IN CLOSE PROXIMITY TO THE DAMAGED STAIRWAY AND WALKWAY. |
03/19/2022 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ALL DOCS AND PHOTOS ON ONBASE, CLOSE CASE |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T22DV01910
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
03/18/2022 | CONTACTED IN PERSON |
03/18/2022 | NOTICE AND ORDER ISSUED |
03/18/2022 | VIOLATION CLOSED |
03/18/2022 | STRUCTURE SECURED BY ??? |
03/18/2022 | CALLBACK |