Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T22DV01869
Case Details
Entered Date:
03/16/2022
Applicant:
CMP FAMILY LIVING TR
Description:
HOUSE FIRE
Completed Inspections
Case Status: COMPLIAN
Case Number: T22DV01869
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
03/16/2022 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CAL OUT BY TFD: THERE IS FIRE DAMAGE TO THE REAR BEDROOM'S INTERIOR WALLS AND CEILING COVERING (SHEETROCK). THERE ARE 2 RAFTERS WITH SAW CUTS FROM THE 4 X 4 ROOF CUT OUT BY TFD. THERE ARE 2 CEILING JOIST WITH SURFACE CHARRING ON AN AREA AT 2 FEET. THE 4 X 4 WINDOW AND OPENING SUSTAINED DAMAGE. THE INTERIOR DOOR AND FRAME ALSO DAMAGED. THE EXTERIOR PLYWOOD SOFFIT WAS TORN DOWN AREA EST AT 2 FEET BY 16 FEET. THE ADJACENT BATHROOM HAS A 2 X 2 CEILING INSPECTION HOLE. ELECTRICAL: THE REAR BEDROOM HAS BURNT AND BARE WIRING IN THE ATTIC AREA ALONG WITH BURNT DEVICES INSIDE THE OUTLETS. TEP DID DISCONNECT POWER. PLUMBING: SWG DID PIN METER OFF MECHANICAL: HEAVY SMOKE THROUGHOUT THE DWELLING REMARKS: PERMIT REQUIRED FOR REPAIRS, THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY. |
03/19/2022 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ALL DOCS AND PHOTOS IN ON BASED. CLOSE CASE |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T22DV01869
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date | Name |
03/16/2022 | CONTACTED IN PERSON |
03/16/2022 | NOTICE AND ORDER ISSUED |
03/16/2022 | VIOLATION CLOSED |
03/16/2022 | STRUCTURE SECURED BY ??? |
03/16/2022 | CALLBACK |