Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

02/25/2022

Applicant:

VILLA SORRENTO LLC ATTN ARIZONA STATUTORY AGENT LLC

Description:

TFD, APARTMENT FIRE UNIT 6207

Outstanding Inspections

Case Number: T22DV01481
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T22DV01481
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date Description Inspector Results Comments
02/25/2022 INSP - INITIAL CODE ENFORCMENT GONZALEZ Approved UNIT 6207 IS AN UPPER LEVEL UNIT (2ND FLOOR) HAD A FIRE IN THE KITCHEN AREA, THERE IS EXTENSIVE AMOUNT OF DRYWALL DAMAGE AND WATER DAMAGE. THERE IS HEAVY SMOKE DAMAGE THROUGHOUT THE APARTMENT UNIT. EXTERIOR ROOF EVE MEMBERS HAVE SIGNS OF ALLIGATORING AND SMOKE DAMAGE. THE KITCHEN DOOR EXIT HAS SIGNS OF HEAT DAMAGE TO ITS ASSEMBLY. THE DECKING OUTSIDE OF THE KITCHEN DOOR EXIT HAS SEVERE SIGNS OF WOOD ROT AND IN NEED OF REPLACEMENT. THE EXTERIOR APPLIANCE CLOSET DOORS ARE DAMAGED AND HAVE SIGNS OF WOOD ROT. ELECTRICAL: ALL ELECTRICAL DEVICES NEED TO BE EVALUATED OR REPLACED BY A LICENSE CONTRACTOR. T.E.P. HAS BOOTED THE METER TO DEACTIVATE THE WET AND HEAT DAMAGED DEVICES. NONMETALLIC SHEATHING NEAR KITCHEN DOOR EXITS APPEARS TO HAVE A HEAT BLISTER. HVAC ELECTRICAL CONDUCTORS IS NOT PROTECTED AND IN AN AREA PRONE TO PHYSICAL DAMAGE. ELECTRICAL DOWNSTREAM PANEL IS LOCATED INSIDE A STORAGE CLOSET WITH COMBUSTIBLES AND LACKS OF WORKMAN'S SPACE (PLYWOOD SOFFIT OF SOME SORT INSTALLED INSIDE REDUCING THE REQUIRED WORKSPACE SIZE) PLUMBING: GAS UTILITY HAS BEEN TERMINATED DUE TO PLUMBING HAS ENDURED HEAT FROM THE FIRE. MECHANICAL: HVAC SYSTEM HAS BEEN INSTALLED WITHOUT PERMITS IN A NON-CODE COMPLAINT MANNER. ITS CONDUCTORS ARE EXPOSED AND NOT PROTECTED FROM PHYSICAL DAMAGE. UNIT HAS BEEN POSTED UNFIT TO OCCUPY UNTIL ALL PROPER PERMITS ARE OBTAINED FOR THE RESTORATION. PROPERTY MANAGER IS AWARE OF VIOLATIONS AND THE NEED TO OBTAIN PERMITS. PROPERTY MAINTENANCE HAS SECURED THE UNIT.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T22DV01481
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
02/25/2022 CONTACTED IN PERSON
03/09/2022 CONTACTED BY MAILING
02/25/2022 NOTICE AND ORDER ISSUED
03/09/2022 VIOLATION CLOSED
02/25/2022 CALLBACK

Documents

File Name Document Type  
INDEMNIFICATION, NOTICE AND ORDER.PDF DOCUMENTS VIEW
IMG_4205.JPG IMAGES VIEW
IMG_4204.JPG IMAGES VIEW
IMG_4203.JPG IMAGES VIEW
IMG_4202.JPG IMAGES VIEW
IMG_4211.JPG IMAGES VIEW
IMG_4210.JPG IMAGES VIEW
IMG_4209.JPG IMAGES VIEW
IMG_4208.JPG IMAGES VIEW
IMG_4207.JPG IMAGES VIEW
IMG_4216.JPG IMAGES VIEW
IMG_4215.JPG IMAGES VIEW
IMG_4214.JPG IMAGES VIEW
IMG_4213.JPG IMAGES VIEW
IMG_4212.JPG IMAGES VIEW
IMG_4221.JPG IMAGES VIEW
IMG_4220.JPG IMAGES VIEW
IMG_4219.JPG IMAGES VIEW
IMG_4218.JPG IMAGES VIEW
IMG_4217.JPG IMAGES VIEW
IMG_4244.JPG IMAGES VIEW
IMG_4241.JPG IMAGES VIEW
IMG_4230.JPG IMAGES VIEW
IMG_4222.JPG IMAGES VIEW