Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

02/23/2022

Applicant:

SAMUEL PFANNKUCHE

Description:

tfd requesting code enforcement for a car into building

Case Violations

Case Number: T22DV01427
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 1
Violation Date Code Statue
02/23/2022 CONTACTED BY PHONE

Completed Inspections

Case Status: COMPLIAN
Case Number: T22DV01427
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
02/23/2022 INSP - INITIAL CODE ENFORCMENT JVALDEZ Approved EMERGENCY CALL OUT BY TFD: THE VEHICLE IMPACT WAS TO THE NORTHWEST SIDE OF THE DWELLING'S TV ROOM. THERE IS SEVERE DAMAGE TO THE DWELLING'S DOUBLE BRICK WALL. THE NORTH WALL DAMAGED AREA IS ESTIMATED AT 8 FEET IN HEIGHT BY 9 FEET IN LENGTH, IN THIS WALL THERE WAS A 4 X 5 WINDOW DESTROYED WITH NO SUPPORT TO THE WOOD HEADER AND STEEL LINTEL. THE REMAINING DOUBLE BRICK WALL AREAS IN THE NORTH WALL AND THE CORNER HAVE SEPARATIONS BETWEEN THE DOUBLE BRICKS WITH DEEP CRACKS IN THE MORTAR JOINTS ALONG WITH LOOSE BRICKS. THE WALLS ALSO HAS CRACK IN THE PLASTER NEAR THE CEILING AREA. THE WEST WALL HAS MULTIPLE CRACKS FROM ΒΌ INCH TO 1-INCH-DEEP IN THE INTERIOR'S PLASTER WHICH RUN 7 FEET, THERE ARE BRICKS WITH SEPARATIONS NEAR THE CORNER AREAS. DAY LIGHT IS VISIBLE FROM THE CRACKS. THE EXTERIOR WAS HAS MULTIPLE BRICK WHICH HAVE SHIFTED OUTWARDS. ELECTRICAL: THERE IS ONE OUTLET WITH A DUPLEX RECEPTACLE NEAR THE IMPACTED CORNER, THE CEILING HAS MULTIPLE RECESS LIGHT FIXTURES. POWER WAS TURNED OFF TO THE TV ROOM WITH CIRCUIT BREAKER IDENTIFIED AS LINE 2 ON THE SERVICE PANEL. THIS EFFECTED POWER TURN OFF TO THE BEDROOM AND AN INTERIOR WALL AND OUTLETS TO THE BATHROOM. PLUMBING N/A MECHANICAL: N/A REMARKS: PERMIT REQUIRED FOR REPAIRS, THE DWELLING WAS CONDEMNED, UNFIT TO OCCUPY DUE TO STRUCTURAL DAMAGE AND POWER DISCONNECT. THE DAMAGED OPENING WAS SECURED BY BOARDING, A 4 X 4 MAKE UP POST WAS INSTALLED TO SHORE UP THE HEADER. CODE ENFORCEMENTS ORDERS INCLUDE CIRCUIT BREAKER: IDENTIFIED AS LINE 2, SHALL REMAIN OFF, DAY TIME ACCESS TO HOME ALLOWED, GUEST HOUSE OK TO OCCUPY.
03/11/2022 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL DOCS AND PHOTOS IN ONBASE, CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T22DV01427
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
02/23/2022 CONTACTED IN PERSON
02/23/2022 NOTICE AND ORDER ISSUED
02/23/2022 VIOLATION CLOSED
02/23/2022 STRUCTURE SECURED BY ???
02/23/2022 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
1746 NOV.PDF DOCUMENTS VIEW
1746 E GRANT RD.PDF DOCUMENTS VIEW
20220223_111433.JPG DOCUMENTS VIEW
20220223_110133.JPG DOCUMENTS VIEW
20220218_081610.JPG DOCUMENTS VIEW
20220218_071435.JPG DOCUMENTS VIEW
20220215_143629.JPG DOCUMENTS VIEW
20220223_112037.JPG DOCUMENTS VIEW
20220223_121251.JPG DOCUMENTS VIEW
20220223_115315.JPG DOCUMENTS VIEW
20220223_112103.JPG DOCUMENTS VIEW
20220223_112056.JPG DOCUMENTS VIEW
20220223_112046.JPG DOCUMENTS VIEW
20220223_133216.JPG DOCUMENTS VIEW
20220223_133021.JPG DOCUMENTS VIEW