TPD CALL: Unsafe electrical exposed wires coming from an electrical box on the exterior of the house.

Completed Inspections

Case Status: COMPLIAN
Case Number: T22DV00670
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
01/26/2022 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TPD: THE REAR GUEST HOUSE HAS A 125 PANEL WITH EXPOSED UNPROTECTED, SPLICED CONDUCTORS FROM A CORD CABLE CONNECTED TO A 30 AMP BREAKER. THE PANEL IS NOT PROPERLY SECURED TO THE BUILDING. THE PANEL FEEDERS FROM THE SERVICE AREA ARE RESTING ON TOP OF THE SHED. THE SHED HAS AN OUTLET WITH EXPOSED CONDUCTORS AND A UNSECURED RECEPTACLE. NEXT TO THE SHED AREA IS AN UNPROTECTED WATER HEATER WITH UNPROTECTED EXPOSED WIRING. THE SERVICE HAS EMT CONDUCT WHICH ENTERS A JUNCTION BOX, NOT RATED FOR OUTDOOR AND ARE LOCATED NEXT TO THE SERVICE ENTRANCE. THIS JUNCTION BOX HAS MULTIPLE WHITE CONDUCTS WHICH ARE TAPED WITH BLACK CONDUCTS WHICH FEED THE 125 AMP PANEL DOWNSTREAM. TUCSON POLICE SHARED INTERIOR PHOTOS OF UNSANITARY LIVING CONDITIONS SUCH AS: DEAD ROACHES IN THE KITCHEN AREA, EXTENSION CORDS BEING USED AS PERMANENT WIRING. A WIRE ENTERING THE CLOSET AREA AND EXITING TO AN UNKNOWN DESTINATION. EXCESSIVE AMOUNT OF STORAGE BLOCKING THE BEDROOM WINDOW. OVERALL: THE POWER TO THE MAIN SERVICE WAS DISCONNECT DUE TO UNAPPROVED, HAZARDOUS WIRING METHODS. THE INTERIOR HAS UNSANITARY AND UNSAFE LIVING CONDITIONS. ALL DWELLINGS ON THE PROPERTY ARE CONDEMNED UNFIT TO OCCUPY.
01/28/2022 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL DOCUMENTS LOADED ONTO ONBASE, AREA INSPECTOR SHALL ADDRESS ALL PROPERTY MAINTENANCE CODE VIOLATIONS AND REMOVE JUNK MOTOR VEHICLES . CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T22DV00670
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
01/26/2022 CONTACTED BY PHONE
01/26/2022 NOTICE AND ORDER ISSUED
01/26/2022 VIOLATION CLOSED
01/26/2022 STRUCTURE SECURED BY ???

Documents

File Name Document Type  
20220126_111406.JPG DOCUMENTS VIEW
20220126_112135.JPG DOCUMENTS VIEW
20220126_121619.JPG DOCUMENTS VIEW
20220126_111406.JPG DOCUMENTS VIEW
20220126_111359.JPG DOCUMENTS VIEW
20220126_111406.JPG DOCUMENTS VIEW
20220126_111524.JPG DOCUMENTS VIEW
20220126_111507.JPG DOCUMENTS VIEW
20220126_121055.JPG DOCUMENTS VIEW
20220126_111059.JPG DOCUMENTS VIEW
1743 NOV.PDF DOCUMENTS VIEW