Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

PRO is currently experiencing an outage. Some documents and records may not be available on PRO momentarily. We apologize for the inconvenience and are working to restore full access.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

11/14/2021

Applicant:

SILVERLAKE MHC PARTNERS LLC

Description:

MOBILE HOME FIRE

Outstanding Inspections

Case Number: T21DV08124
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV08124
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/14/2021 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD: THERE IS DAMAGE TO THREE WINDOWS IN THE LIVING AREA AND THE FRONT DOOR. THE INTERIOR SHEETROCK HAS MULTIPLE INSPECTION HOLES IN THE CEILING AND WALLS. THE FLOORING IS SATURATED IN WATER. ELECTRICAL: THE INTERIOR PV WIRING, THE SOLAR CONTROLLER, SUB PANEL AND OTHER ELECTRICAL DEVICES IN THE HALLWAY AND LIVING ROOM ARE MELTED OR HAVE SEVERE HEAT DAMAGE. THIS MOBILE HOME PARK IS MASTER METERED, THE BREAKERS TO THE PEDESTAL ARE OFF, TEP DID REMOVE THE METER AND INSTALL A COVER PLATER OVER THE METER SOCKET. THE PULL OUT DISCONNECT TO THE PV SYSTEM WAS REMOVED. NOTE: THE SOUTH SIDE PATIO ESTIMATED AT 12 X 16 HAS MULTIPLE PV PANELS AS THE ROOF AND PANELS ON THE SIDE OF THE WOOD FRAMED PATIO. THE BATTERIES ARE IN THE OPEN NOT PROTECTED. PLUMBING: SWG DID PIN THE METER OFF. MECHANICAL: THE AIR HANDLERS ARE DAMAGED AND MELTED IN THE LIVING ROOM AND BEDROOM. THE ENTIRE HOMES SHEETROCK IS COVERED IN SMOKE. REMARKS: PERMIT REQUIRED FOR REPAIRS, THE CITY DID PIN THE FRONT DOOR SHUT THE UNIT WAS CONDEMNED UNFIT TO OCCUPY.
11/30/2021 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL DOCS IN ONBASE, CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T21DV08124
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
11/14/2021 CONTACTED IN PERSON
11/14/2021 NOTICE AND ORDER ISSUED
11/14/2021 VIOLATION CLOSED
11/14/2021 STRUCTURE SECURED BY ???
11/14/2021 CALLBACK