Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

08/17/2021

Applicant:

LUIS A PEREZ

Description:

REPORT THAT CIELING AND GARAGE ARE ABOUT TO COLLAPSE FROM WATER DAMAGE

Case Violations

Case Number: T21DV05445
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 2
Violation Date Code Statue
08/19/2021 T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected.
08/19/2021 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV05445
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/17/2021 INSP - INITIAL CODE ENFORCMENT VIDAL Approved The office called that the ceiling was ready to fall. Arrived and met with the tenant and the ceiling in the garage was not ready to fall and has a roof leak on the upper floor. The leak has been for some time and has water stains in different areas. Has one section where the edges are peeling from falling apart on the drywall from the constant moisture in the drywall from the water leaks in the roof. This has been going for about 3-years. Will do a N.O.V. RV.
01/12/2022 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved Not able to make contact with the tenant and not able to leave messages. At this time the case will be closed. The owner was going to make the needed repairs when the tenant moved out. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T21DV05445
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
08/19/2021 CONTACTED BY MAILING
08/19/2021 NOTICE OF VIOLATION ISSUED