Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.
Case: T21DV04619
Case Details
Entered Date:
07/21/2021
Applicant:
DBR INVESTMENTS PROP LLC 49.50% &
Description:
elevator malfunction
Completed Inspections
Case Status: COMPLIAN
Case Number: T21DV04619
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
07/21/2021 | INSP - INITIAL CODE ENFORCMENT | GONZALEZ | Approved | TFD CALL OUT, UPON ARRIVAL NO BUILDING DAMAGE HAS OCCURRED. NO ELECTRICAL, PLUMBING OR MECHANICAL HAS BEEN AFFECTED, ELECTRONIC COMPONENTS TO THE ELEVATOR'S MOTOR IS MALFUNCTIONING CAUSING OIL TEMPERATURE TO RISE (TFD REPORTED HEAT REACHED 200 DEGREES FAHRENHEIT) CAUSING THE OIL TO SMOKE AND PRODUCE OBNOXIOUS SMELL. PROPERTY MANAGER ON-SITE WITH TENANTS, CODE ENFORCEMENT WAS NOT ABLE TO ISOLATE POWER TO THE ELEVATOR MOTOR DEVICE WITHOUT TERMINATING POWER TO THE BUILDING. POSTED UNFIT TO OCCUPY POWER WAS LOCKED AT THE OFF POSITION TO PREVENT SWITCH GEAR TO BE TURNED BACK ON AND CAUSING FURTHER DAMAGE. PROPERTY MANAGER ACKNOWLEDGE DOCUMENTS AND WILL SECURE BUILDING UNTIL REPAIRS ARE MADE OR ABLE TO ISOLATE THE POWER FROM MALFUNCTIONING DEVICE. |
07/22/2021 | INSP - FOLLOW UP CODE ENFORCE | GONZALEZ | Approved | OTIS ELEVATOR COMPANY ONSITE WITH PROPERTY MANAGER, POWER HAS BEEN REINSTATED AFTER CONFIRMATION FROM THE CONTACTOR POWER HAS BEEN ISOLATED FROM THE ELEVATOR MOTOR. CONTRACTOR HAS LOCKED AND TAGGED OUT ASSOCIATED SWITCH GEAR TO PREVENT ACTIVATION OF POWER TO MALFUNCTIONING DEVICES. PROPERTY MANAGER HAS BEEN GIVEN THE APPROVALS TO REMOVE UNFIT TO OCCUPY PLACARD AND CONTINUE WITH BUSINESS OPERATION. ONCE CONTRACTOR EVALUATES THE SYSTEM OF THE MALFUNCTIONING COMPONENTS TO THE MOTOR WILL BASE IT DETERMINATION OF REPAIR AND POTENTIAL OF NEEDING A PERMIT FROM THE STATE OF ARIZONA. ADOSH ELEVATOR INSPECTOR HAS BEEN CONTACTED REGARDING ELEVATOR MALFUNCTIONING. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T21DV04619
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date | Name |
07/22/2021 | CONTACTED BY PHONE |
07/22/2021 | CONTACTED IN PERSON |
07/22/2021 | NOTICE AND ORDER ISSUED |
07/22/2021 | VIOLATION CLOSED |