Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING
Address:

Entered Date:

07/13/2021

Applicant:

ANGELENO HOMES LLC ATTN CHAD

Description:

unit 6. leaking roof and now it's falling in to the home sheetrock coming off,assuming there may be mold due to the rain and humidiy.

Outstanding Inspections

Case Number: T21DV04405
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV04405
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
07/13/2021 INSP - INITIAL CODE ENFORCMENT GONZALEZ Approved UPON INSPECTION, THE INTERIOR CEILING DRY WALL IS MOIST AND HANGING DUE TO WATER PENETRATING THE UNIT. THERE IS AN ENERGIZED ELECTRICAL CEILING FAN IN THE NEAR VICINITY OF THE WATER INTRUSION. AT THE EXTERIOR OF THE BUILDING THERE IS A MAIN SERVICE PANEL LABELED "302 W. FLORES PANEL EA" THAT HAS AN ENERGIZED NON APPROVED 30AMP-125 RECEPTACLE BEING ENERGIZED BY TYPE NM 10 AWG NONMETALLIC SHEATH CABLE IN A NON-CODE COMPLAINT MANNER. THERE IS AN ACTIVE ROOF LEAK NEAR THE VICINITY OF THE INTERIOR CEILING FAN. THE INTERIOR DRY WALL HAS PARTIALLY COLLAPSED; THE PROPERTY OWNER HAS THE ROOF SCHEDULED TO BE REPAIR ON 7/14/2021. THERE ARE CURRENT RAIN STORMS IN THE CITY LIMITS FORECAST, AND JULY 12 2021 WE RECENTLY HAD A SEVERE RAIN STORM IN THE CITY LIMITS. DUE TO THE LEAK IS NEAR ELECTRICAL AND BEING OCCUPIED THE CITY WILL CONDEMN THE UNIT AND ORDER THE POWER TO REMAIN OFF UNTIL ROOF REPAIRS ARE MADE TO PROTECT THE OCCUPANTS AND THE INTERIOR OF THE STRUCTURE FROM FURTHER DAMAGE. OWNER HAS BEEN ADVISED ONCE REPAIRS ARE MADE THE UNIT MAYBE RE-OCCUPIED. POSTED UNFIT TO OCCUPY ON THE UNIT, AND ORDERS HAS BEEN LEFT WITH OCCUPANTS. THE NON APPROVED RECEPTACLE HAS BEEN REMOVED BY OWNERS ELECTRICIAN

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T21DV04405
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
07/13/2021 CONTACTED BY PHONE
07/14/2021 NOTICE AND ORDER ISSUED
07/14/2021 NOTICE OF VIOLATION ISSUED
07/14/2021 VIOLATION CLOSED

Documents

File Name Document Type  
IMG_2384.JPG IMAGES VIEW
IMG_2383.JPG IMAGES VIEW
IMG_2382.JPG IMAGES VIEW
IMG_2381.JPG IMAGES VIEW
64790912353__E13FCE07-FD07-40BA-BB13-5D3A32C1D1E8.JPG IMAGES VIEW
IMG_2399.JPG IMAGES VIEW
IMG_2398.JPG IMAGES VIEW
IMG_2387.JPG IMAGES VIEW
IMG_2386.JPG IMAGES VIEW
IMG_2385.JPG IMAGES VIEW
IMG_2401.JPG IMAGES VIEW
IMG_2400.JPG IMAGES VIEW
NOTICES.PDF DOCUMENTS VIEW