Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RES: MINIMUM HOUSING

Entered Date:

06/16/2021

Applicant:

ALVARO ESCALANTE

Description:

No A/C has not been working since last summer

Case Violations

Case Number: T21DV03807
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 13
Violation Date Code Statue
07/14/2021 T.C. Ch. 16, Sec. 16-11(a)(1) The presence and operations of window openings, size and condition of exits, bars, grills, grates covering windows and openings shall allow for safe and rapid egress in emergency situations. At least one window and all doors in living/sleeping rooms in dwelling units must have an operable release mechanism that allows safe and rapid egress without the use of separate tools.
07/14/2021 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
07/14/2021 T.C. Ch. 16, Sec. 16-11(b) (1) HEATING. Every habitable room within a dwelling unit, guest room, and congregate residence shall be provided with safe heating facilities which are properly installed and maintained in a sound condition and are capable of providing adequate heating, appropriate for the climate, to assure a safe living environment. All heating facilities shall be free from health hazards associated with ventilation, mounting, electrical and gas connections and other defects. Unvented fuel-burning heaters must be of a listed and approved type, and are prohibited as the sole source of heating. Ovens, stoves or ranges, or other cooking appliances cannot be used for the purpose of heating any portion of a dwelling. Listed, portable space heaters may only be used as the sole source of heating on a temporary basis when the permanent heating system is being repaired or replaced.
07/14/2021 T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced.
07/14/2021 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
07/14/2021 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
07/14/2021 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
07/14/2021 T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced.
07/14/2021 T.C. Ch. 16, Sec. 16-12(f) ADDRESS DISPLAY. (1) General requirements: a. All structures, whether new or existing, designed for human occupancy or use which have an assigned address shall display the address in a manner to be plainly legible and visible from the street or road fronting the property. e. The complete address shall be displayed on all corner buildings at a street intersection, for each side of the building facing any street. f. Addresses shall be displayed and visible from both directions of approaching vehicular travel. g. Numbers and letters shall be made of durable and clearly visible material. Paint shall not be considered durable for building addresses. h. Numbers and letters shall be of colors contrasting with the background of the sign or wall to which they are attached. i. Numbers and letters shall have a minimum proportion ratio of height to width of six to one (6:1). The formula is w = h/6, where w is width and h is height in inches. j. Numbers shall not be spelled. k. All height requirements stated in this section are minimum sizes.
07/15/2021 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
07/15/2021 T.C. Ch. 16, SEC. 16-21. REGISTRATION OF RESIDENTIAL RENTAL PROPERTY. An owner of residential rental property shall maintain with the assessor in the county where the property is located information required by this section in a manner to be determined by the assessor. (c) Residential rental property shall not be occupied if the information required by this section is not on file with the county assessor. This subsection does not affect any lease existing on August 6, 1999. (e) A person who fails to comply with any provision of this subsection is responsible for a civil infraction and shall be assessed a civil penalty of one thousand dollars ($1,000.00), plus an additional one hundred dollars ($100.00) for each month after the date of the original violation until compliance occurs. The court shall not suspend any portion of the civil penalty provided by this subsection.
07/15/2021 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
07/15/2021 T.C. Ch. 16, Sec. 16-13(h) OUTDOOR STORAGE Outdoor storage on residential properties is prohibited under the following conditions: 1. When stored in the front yard. 2. When stored in the side yard or rear yard and is not screened by a minimum five foot high solid wall or opaque fence. 3. When exceeds 25% of the total lot area. 4. When stored in an open covered porch that is visible from beyond the boundaries of the lot. 5. When stored in an open carport that is visible from beyond the boundaries of the lot where the amount of storage restricts an automobile from being properly stored within the carport. A double carport will require enough space to store two automobiles. 6. When storage items include garbage, refuse or debris.

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV03807
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/16/2021 INSP - INITIAL CODE ENFORCMENT VIDAL Approved The office called that the tenant has no cooling and was near the area. Arrived and no one home. Did call the tenant and was working on getting assistance on paying the back rent. Will meet in the morning tomorrow at 7:30 am. Did talk to the owner and will also be on site in the morning. RV.
06/17/2021 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved Met with the tenant and went over issues on the house. The AC on the roof and the cooler have not been used since last year and not connected for use. Has security bars that are not able to open due to plaster into the wall and not set up for break away on the bedroom. The front door has bolt type lock and not working propertly, the exterior doors are not sealed and lacking the weather-stripping, no working smoke detectors, lacking GFCI's in the bathroom and kitchen, has grounded outlets on a 2-wire system, some loose boxes in the wall, the hall bathroom is leaking and not able to stop the water from leaking, ceiling fan no working due to missing a blade and some are loose. Will be doing the N.O.V. Will check in 5 days. RV.

Completed Activity Special Conditions

Case Description - RES: MINIMUM HOUSING
Case Number - T21DV03807
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
07/14/2021 CONTACTED BY MAILING
07/14/2021 NOTICE OF VIOLATION ISSUED