Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING
Address:

Entered Date:

05/26/2021

Applicant:

LULU MOHAMMED HISHAM

Description:

FTD DIVERSION - BUILDING STRUCTURE CHECK EVENT # F211460038

Outstanding Inspections

Case Number: T21DV03132
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
EMERGENCY CALL OUT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV03132
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/26/2021 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TFD:THERE IS SEVERE FIRE DAMAGE TO ¾ OF THE ROOF ASSEMBLY AND SUPORT MEMBERS, THE ROOF AREA IS ESTIMATED AT 22 X 66 FEET. THE OVER 30 ROOF JOISTS HAVE DEEP CRACKS WITH CHARRED AREAS VISIBLE ON THE EDGES. DECKING HAS SOME AREAS WITH DEEP CRACKS. THERE IS A 4 X 8 ROOF CUT OUT. THE NORTH WALL HAS 2 X 6 STUD WITH DEEP CRACK AND CHARRED AREAS. THE SOUTH WALL HAS DAMAGED PLYWOOD AS WALL COVERING, THERE IS ONE WINDOW WINDOW DAMAGED. THE OPENING INTO THE MAIN BUILDING IS A PORCH AND IT HAS SEVERE DAMAGE TO THE 6 X 6 WOOD BEAM AND MULTIPLE RAFTERS, THERE IS AN ATTACHED STORAGE ROOM WITH DAMAGED WOOD SIDING. THE MAIN BUILDING HAS 2 INSPECTION HOLE IN THE CEILING. THE GARAGE IS DIVIDED INTO TWO PARTS. THE REAR PARTITIONED SECTION OF THE GARAGE IS ESTIMATED AT 22 X 24. THERE ARE (3) 6 X 6 POSTS WITH DEEP CRACKS SUPPORTING ROOF LOAD ON THE NORTHSIDE OF THE BUILDING THE SOUTHSIDE HAS FIRE DAMAGE TO THE PANEL BOARD WALL COVERING. THE BUILT UP WALL, STUDS AND BEAM ALSO HAS SEVERE DEEP CRACKS. ELECTRICAL: THERE ARE MULTIPLE NM CABLES EXPOSED AND BURNT IN THE GARAGE AREA, THE INTERIOR PANEL ALONG WITH ELECTRICAL DEVICES ARE BURNT, TEP DISCONNECT POWER TO THE MAIN DISCONNECT. PLUMBING: N/A MECHANICAL: HEAVY SMOKE IN THE INTERIOR REMARKS: THE BUILDING WAS CONDEMNED, NO OCCUPANCY. DEMOLITION AND OR REPAIR PERMIT REQUIRED
07/07/2021 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL DOCS IN ONBASE. CLOSE CASE

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T21DV03132
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
05/26/2021 CONTACTED IN PERSON
05/26/2021 NOTICE AND ORDER ISSUED
05/26/2021 VIOLATION CLOSED
05/26/2021 STRUCTURE SECURED BY ???
05/26/2021 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
2307 NOV.PDF DOCUMENTS VIEW
2307 N STONE AVE.PDF DOCUMENTS VIEW
20210526_100420.JPG DEVPLANS VIEW
20210526_100550.JPG DEVPLANS VIEW
20210526_100606.JPG DEVPLANS VIEW
20210526_101052.JPG DEVPLANS VIEW
20210526_101057.JPG DEVPLANS VIEW
20210526_101119.JPG DEVPLANS VIEW
20210526_101408.JPG DEVPLANS VIEW
20210526_101641.JPG DEVPLANS VIEW
20210526_101849.JPG DEVPLANS VIEW
20210526_101858.JPG DEVPLANS VIEW
20210526_101908.JPG DEVPLANS VIEW
20210526_102310.JPG DEVPLANS VIEW
2307 N STONE AVE.PDF DEVPLANS VIEW