Case Details

Status:

Closed - Resolved

Type:

TPD REQUESTS, COMMUNITY SURVEY OF EXTERIOR VIOLATIONS OF ALL COMMON AREAS AND EXTERIOR OF BUILDINGS ON SITE.
Address:

Entered Date:

05/06/2021

Applicant:

N/A

Description:

Completed Inspections

Case Status: Closed - Resolved
Case Number: T21DV02720
Case Description: TPD REQUESTS, COMMUNITY SURVEY OF EXTERIOR VIOLATIONS OF ALL COMMON AREAS AND EXTERIOR OF BUILDINGS ON SITE.
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/03/2021 COT - ENFC - Code Enforcement - Initial Passed {Activity date: 05/03/2021; Status: Approved; Inspector: BERMUDEZ; Comment: Entered by BERMUDEZ - ON SITE WITH TPD, OFFICER YORK; FOR COMMUNITY SURVEY TO WALK THE COMPLEX FOR EXTERIOR VIOLATIONS OKAY PER SUPER MR. VIOLATIONS WERE FOUND AS FOLLOWS; DEAD TREES OR SHRUBS ON THE PROPERTY. PERIMETER CHAIN LINK FENCING IS CUT AND IN DISREPAIR IN A COUPLE OF AREAS. OUTDOOR STORAGE VISABLE WITHIN THE COMPLEX AND STREET (UNIT FRONT DOOR AREAS, NORTH FRONT OFFICE AREA, POOL AREA) TO INCLUDE BUT NOT LIMITED TO FUNITURE, APPLIANCES AND CONSTRUCTION MATERIALS. GRAFFITI FOUND THROUGH OUT THE COMPLEX ON ALL BUILDINGS, 1ST, 2ND AND 3RD FLOORS TO INCLUDE BUT NOT LIMITED TO, INTERIOR OF STAIRWELLS, HALLWAYS AND BALCONY WOOD HAND RAILS, WINDOWS, DUMPSTERS, ETC. REFUSE AND DEBRIS THROUGHOUT THE PROPERTY TO INCLUDE BUT NOT LIMITED TO; NEAR DUMPSTERS, POOL AREA, STAIRWELLS, BALCONIES, UNIT FRONT DOOR AREAS, ETC. ALSO STAIRWELLS, DECKS, LANDINGS, STEPS, UNDER STAIRWELLS AND SIDEWALKS THROUGHOUT THE COMPLEX HAVE REFUSE AND DEBRIS ON THEM TO INCLUDE GUM, URINE AND FECES, MUST BE POWERWASHED AND MAINTAINED. MULTIPLE DEAD MICE FOUND ON THE PROPERTY AS WELL AS DEAD BIRDS. LIVE ROACHES FOUND ALL AROUND EXTERIOR OF BUILDINGS AND IN HALLWAYS. AN EXCESS BOARDING OF 180 DAYS TO UNIT OPENINGS THROUGHOUT THE COMPLEX TO INCLUDE BUT NOT LIMITED TO DOOR AND WINDOW OPENINGS. MULTIPLE BROKEN WINDOWS FOUND THROUGHOUT THE COMPLEX TO INCLUDE BUT NOT LIMITED TO UNITS, A206, A208, A307, B204 AND FRONT OFFICE WINDOW. MULTIPLE ENTRY DOORS TO UNITS ARE IN DISREPAIR, DAMAGED OR MISSING FRAMES, UNABLE TO CLOSE, ETC. MULTIPLE COAX CABLES THROUGHOUT COMPLEX ARE HANGING OR TIED TO OTHER EXTERIOR AREAS SUCH AS BUT NOT LIMITED TO; STAIRWELLS, SPRINKLER HEADS AND OTHER FIXED ITEMS OBSTRUCTING THE EGRESS AREAS AND OR ENCROACHING ON. GUTTER DRAINAGE SYSTEM TO EXTERIOR BUILDINGS ARE IN DISREPAIR AND OR MISSING. (WHILE CE AND TPD ON SITE A PORTION OF THE GUTTER WAS REMOVED BY PROPERTY MGR AND MAINT. DUE TO SAFETY ISSUE OF THE GUTTER SWAYING DANGEROUSLY IN THE WIND, WAS IN DISREPAIR AND NOT ANCHORED PROPERTY) HOLES FOUND ON EXTERIOR WALLS OF STUCCO BUILDING, EXPOSING CHICKEN WIRE AND WOOD FRAMING. HOLES ALSO FOUND IN DRYWALL ON INTERIOR HALLWAYS AND LAUNDRY ROOMS. UNIT NUMBERS MISSING FROM SOME APARTMENT UNITS. MULTIPLE WROUGHT IRON DOORS TO UNITS, HALLWAY DOORS AND LAUNDRY ROOMS, TO INCLUDE THE MESH SCREEN ATTACHED TO WROUGHT IRON FRAMES. POSING AN ATTRACTIVE NUISANCE TO THE PUBLIC. WOOD STAIRWELLS, DECKS, LANDINGS, STEPS AND HAND RAILS ARE IN DISREPAIR, LOOSE, MISSING SLATS, IN ROTTED STATE, DETERIORATING AND LACKING PROPER WEATHER PROTECTANT. A/C UNITS TO MULTIPLE UNITS TO INCLUDE BUT LIMITED TO A202, A206, A306, ETC. ARE IN DISREPAIR AND MISSING THE REAR COVER PANEL, EXPOSING WIRING AND COILS, POSING AN ATTRACTIVE NUISANCE TO THE PUBLIC AND SAFETY HAZARD TO TENANT WITHIN UNIT. ALSO APPLIANCES IN LAUNDRY ROOM NOT PROPERLY INSTALLED. (DRYER HOSE VENT DISCONNECTED AND FILLING ROOM WITH LINT) EXTERIOR LIGHTING VIOLATIONS TO INCLUDE BUT NOT LIMITED TO MISSING COVERS, SHEILDS, HANGING FROM EXTERIOR WALLS, NO LIGHTING IN HALLWAYS, EXPOSED WIRING. ELEVATORS NOT WORKING PROPERLY, DAMAGED PUSH BUTTONS, EXPOSING WIRING WITHIN. EXPOSED WIRING AT ELECTRICAL JUNCTION BOXES FOUND WITHIN ACCESSORY STRUCTURE RAMADA NEAR POOL, ELECTRIC CONDUIT HANGING. EXTERIOR BUILDING AND LAUNDRY OUTLETS MISSING COVERS. ACCESSORY WOOD RAMADA STRUCTURE NEAR POOL IN DISREPAIR, ROTTED WOOD, DETERIORATING, MISSING WOOD BEAMS/RAFTERS AND WOOD PROTECTIVE TREATMENT. DAMAGED SOLAR RAMADA AT NORTH END PROPERTY BEING SUPPORTED BY 2X4 WOOD POST WHICH IS ATTACHED TO SMALLER POST TO MAKE IT LONGER. (BARRICADES WERE PLACED BEFORE END OF DAY TO SECURE AREA FROM PUBLIC) FOUND MULTIPLE FIRE ALARMS IN PULLED AND OR ENGAGED POSITION, SPRINKLER HEADS ZIPPED TIED HOLDING UP COAX CABLES AND OR ANTENAS, ROLL OF ELECTRICAL TAPE OVER SPRINKLER HEAD, MISSING FIRE EXTINGUISHERS, ALL REMAINING EXTINGUISHERS ARE OUT DATED FROM 2015 AND 2018 INSPECTIONS. WILL FOWARD THIS PORTION TO TFD, BY WAY OF EMAIL PER SUPER MR. WILL ISSUE A NOTICE FOR ALL VIOLATIONS FOUND.}
09/13/2022 COT - ENFC - Code Enforcement - Follow Up Passed {Activity date: 09/13/2022; Status: Approved; Inspector: VALDEZ; Comment: Entered by VALDEZ - CLOSED COURT CASE DUE TO PNI PROJECT} ; {Activity date: 07/15/2022; Status: Approved; Inspector: VALDEZ; Comment: Entered by VALDEZ - 7/15/2022 ONSITE INSPECTION; BELOW ARE THE CODE VIOLATIONS PENDING A WOOD POST ALONG WITH 2 AND ONE BY MEMBERS WERE INSTALLED TO SUPPORT THE 3RD STORY WALKWAY AND THE ROOF LOAD. 2 GUARDS MADE UP OF A 2 X 12 BOARD WAS ALSO INSTALLED. THIS WORK DONE WITHOUT A BUILDING PERMIT. THIS WORK WAS LATER COVERED UP WITH STUCCO AND PAINT. THE STAIRWAY DECK BOARDS ARE LOOSE AND UNEVEN (TRIP HAZARDS) THE WOOD FRAMED GUARDS ARE NOT CODE COMPLAINT AND LOOSE, CURRENTLY ALL WALKWAY GUARDS WITHIN THE FLOOR TO THE 36 INCH ZONE HAVE OPENINGS LARGER THAN 7 INCHES AND A WIDTH OF 8 FEET. THERE ARE MULTIPLE LIGHT FIXTURES IN THE STAIRWAYS, CORRIDORS AND THE EXITS DOORS OF THE UNITS WITCH ARE DAMAGED, SPRAY PAINTED AND NON WORKING. THE LAUNDRY ROOM HAS MISSING COVER PLATE REAR OF DRYER THERE ARE PORTIONS OF THE CHAIN FENCE WITH TORN OPENINGS AND IN DISREPAIR. THERE ARE INOPERABLE GATE (S) WHICH ARE UNSTABLE. THE SHADE STRUCTURE LOCATED NEXT TO THE POOL IS IN DISREPAIR. DOWN SPOUTS AREA DAMAGED. THE INTERIOR OF THE EMPTY POOL HAS REFUSE. THERE ARE ABANDON APPLIANCES THROUGHOUT THE PROPERTY. THERE IS SHEETROCK DAMAGE IN TH LAUNDRY ROOM. ELEVATORS IN BUILDING A AND B ARE NOT FUNCTIONAL/ INOPERABLE. A REPORT OF ELEVATOR REPAIR WAS PROVIDED AFTER THE INSPECTION, AN INSPECTION WILL BE REQUIRED AT THE NEXT FOLLOW DATE. INTERNATIONAL FIRE CODE VIOLATIONS: THE FOLLOWING ITEMS HAVE NOT BEEN ABATED MULTIPLE FIRE EXTINGUISHERS ARE MISSING FROM THEIR CABINETS (I COUNTED AT LEAST 6 EMPTY CABINETS). CABINETS HAVE NOT BEEN SUPPLIED WITH "BREAKER BARS" THAT ARE NEEDED TO HELP ACCESS THE EXTINGUISHERS IN THE CABINETS. FOR THE EXISTING EXTINGUISHERS, RECEIPTS HAVE BEEN PROVIDED FOR THE EXTINGUISHERS, THE RECEIPTS ARE DATED 7/11/21 AND 7/20/21. BECAUSE ONE OF THE RECEIPTS IS MORE THAN A YEAR OLD, ALL EXTINGUISHERS NEED TO BE INSPECTED AND TAGGED BY AN APPROVED FIRE PROTECTION COMPANY, AND THIS NEEDS TO BE DONE AN ANNUAL BASIS. *NOTE: THEFT OF EXTINGUISHERS HAS BEEN RECOGNIZED AS AN ONGOING ISSUE FOR THIS PROPERTY, AND BRIAN HAS BEEN INFORMED ON MULTIPLE OCCASIONS THAT HE HAS THE OPTION OF PROVIDED RESIDENTS WITH INDIVIDUAL EXTINGUISHERS THAT WOULD BE PLACED IN EVERY APARTMENT. BRIAN HAS REFUSED TO PROVIDE INDIVIDUAL EXTINGUISHERS TO RESIDENTS. SMOKE DETECTOR INSPECTION SHEET NEEDS TO BE FILLED OUT AND SIGNED. A REPORT WAS PROVIDED BY BRIAN, BUT NO DETAILS ARE INCLUDED ON THE REPORT AND IT IS NOT SIGNED. AN INSPECTION REPORT NEEDS TO BE PROVIDED FOR THE FIRE ALARM PULL STATIONS/LOCAL ALARMS THAT ARE ON THE PROPERTY. THIS REPORT NEEDS TO BE PROVIDED BY AN APPROVED FIRE PROTECTION COMPANY. VIOLATIONS ABATED FIRE SPRINKLER INSPECTION REPORT IS APPROVED. LOCKS ON FIRE DEPARTMENT RISER ROOM ARE APPROVED. THE BUILDINGS HAVE MULTIPLE BROKEN OR DAMAGED WINDOWS AND DOORS THE WALKWAYS AND STAIRWAY HAVE URINE, FECES AND DEBRIS ON ALL SURFACES, THERE IS REFUSE ON THE OFFICE BUILDINGS ROOF TOP GRANTED 30 DAT EXTENSION } ; {Activity date: 05/31/2022; Status: Approved; Inspector: VALDEZ; Comment: Entered by VALDEZ - HEARING CONTINUED TILL SEPT 13, 2022 AT 0830} ; {Activity date: 05/18/2022; Status: Approved; Inspector: VALDEZ; Comment: Entered by VALDEZ - NOTICE OF VIOLATION TO BE MAILED AND RECORDED} ; {Activity date: 05/18/2022; Status: Approved; Inspector: VALDEZ; Comment: Entered by VALDEZ - SECTION 8 INSPECTION COMPLETED 5-13-2022 REPORT SUBMITTED 5-17-2022} ; {Activity date: 05/09/2022; Status: Approved; Inspector: VALDEZ; Comment: Entered by VALDEZ - FOLLOW INSPECTION WITH GUARDS, THE BUILT UP POST WAS FINISHED WITHOUT A PERMIT OR STRUCTURAL ENGINEER.} ; {Activity date: 05/06/2022; Status: Approved; Inspector: VALDEZ; Comment: Entered by VALDEZ - EXTERIOR CODE VIOLATIONS, THERE ARE BROKEN WINDOWS, LOOSE AND DAMAGED DECK BOARDS, STAIRWELL GUARDS LOOSE AND DAMAGED. A BUILT UP POST AND ADDITIONAL MEMBERS WAS INSTALLED TO SUPPORT THE THIRD STORY WALKWAY THIS WORK WAS DONE WITHOUT A PERMIT. THIS WORK WILL REQUIRE A STRUCTURAL ENGINEERING AND BUILDING PERMIT. THE WALKWAYS WITH URINE, FECES AND DEBRIS ON ALL SURFACES. THERE ARE SPRINKLERS WITH PAINT OVER SPRAY, THERE ARE MISSING PORTABLE FIRE EXTINGUISHERS. THERE ARE ABANDON APPLIANCES, REFUSE AND SHOPPING CARTS THROUGH OUT THE PROPERTY. THE POOL IS EMPTY BUT HAS LITTER. THE SHADE STRUCTURE NEXT TO THE POOL IS IN DISREPAIR.} ; {Activity date: 04/29/2022; Status: Approved; Inspector: VALDEZ; Comment: Entered by VALDEZ - NIGHT INSPECTION WITH TPD , THERE ARE BROKEN, NON FUCTIONING LUMINARES IN ALL FLOORS AND STAIRWELLS} ; {Activity date: 02/10/2022; Status: Approved; Inspector: BERMUDEZ; Comment: Entered by BERMUDEZ - COURT FOLLOW ; NON COMPLIANCE,TOOK PICS FOR COURT.} ; {Activity date: 09/03/2021; Status: Approved; Inspector: BERMUDEZ; Comment: Entered by BERMUDEZ - ON SITE; TOOK PICTURES TO ISSUE COURT CITATION.}

Completed Case Activity

Case Number - T21DV02720
Case Status: Closed - Resolved
Case Description: TPD REQUESTS, COMMUNITY SURVEY OF EXTERIOR VIOLATIONS OF ALL COMMON AREAS AND EXTERIOR OF BUILDINGS ON SITE.
Description Date Status
CONTACTED IN PERSON 04/29/2022 Passed
Other Activity 05/10/2021 Passed
NOTICE OF VIOLATION ISSUED 05/18/2022 Passed
CONTACTED BY MAILING 05/18/2022 Passed
COURT HEARING INFO 05/31/2022 Passed
CERTIFIED RECEIPT CARD 06/09/2022 Passed
CONTACTED BY EMAIL 08/02/2022 Passed
CITATION ISSUED 10/08/2021 Passed