Case: T21DV02720

Parcel: 11108313D


Addresses:

2550 N DODGE BL


Inspection Status: Passed

Inspection History: COT - ENFC - Code Enforcement - Follow Up

Case Number - T21DV02720

Inspection Description - COT - ENFC - Code Enforcement - Follow Up

Inspection Status - Passed

Date Description Inspector Results Comments
09/13/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - CLOSED COURT CASE DUE TO PNI PROJECT
07/15/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - 7/15/2022 ONSITE INSPECTION; BELOW ARE THE CODE VIOLATIONS PENDING A WOOD POST ALONG WITH 2 AND ONE BY MEMBERS WERE INSTALLED TO SUPPORT THE 3RD STORY WALKWAY AND THE ROOF LOAD. 2 GUARDS MADE UP OF A 2 X 12 BOARD WAS ALSO INSTALLED. THIS WORK DONE WITHOUT A BUILDING PERMIT. THIS WORK WAS LATER COVERED UP WITH STUCCO AND PAINT. THE STAIRWAY DECK BOARDS ARE LOOSE AND UNEVEN (TRIP HAZARDS) THE WOOD FRAMED GUARDS ARE NOT CODE COMPLAINT AND LOOSE, CURRENTLY ALL WALKWAY GUARDS WITHIN THE FLOOR TO THE 36 INCH ZONE HAVE OPENINGS LARGER THAN 7 INCHES AND A WIDTH OF 8 FEET. THERE ARE MULTIPLE LIGHT FIXTURES IN THE STAIRWAYS, CORRIDORS AND THE EXITS DOORS OF THE UNITS WITCH ARE DAMAGED, SPRAY PAINTED AND NON WORKING. THE LAUNDRY ROOM HAS MISSING COVER PLATE REAR OF DRYER THERE ARE PORTIONS OF THE CHAIN FENCE WITH TORN OPENINGS AND IN DISREPAIR. THERE ARE INOPERABLE GATE (S) WHICH ARE UNSTABLE. THE SHADE STRUCTURE LOCATED NEXT TO THE POOL IS IN DISREPAIR. DOWN SPOUTS AREA DAMAGED. THE INTERIOR OF THE EMPTY POOL HAS REFUSE. THERE ARE ABANDON APPLIANCES THROUGHOUT THE PROPERTY. THERE IS SHEETROCK DAMAGE IN TH LAUNDRY ROOM. ELEVATORS IN BUILDING A AND B ARE NOT FUNCTIONAL/ INOPERABLE. A REPORT OF ELEVATOR REPAIR WAS PROVIDED AFTER THE INSPECTION, AN INSPECTION WILL BE REQUIRED AT THE NEXT FOLLOW DATE. INTERNATIONAL FIRE CODE VIOLATIONS: THE FOLLOWING ITEMS HAVE NOT BEEN ABATED MULTIPLE FIRE EXTINGUISHERS ARE MISSING FROM THEIR CABINETS (I COUNTED AT LEAST 6 EMPTY CABINETS). CABINETS HAVE NOT BEEN SUPPLIED WITH "BREAKER BARS" THAT ARE NEEDED TO HELP ACCESS THE EXTINGUISHERS IN THE CABINETS. FOR THE EXISTING EXTINGUISHERS, RECEIPTS HAVE BEEN PROVIDED FOR THE EXTINGUISHERS, THE RECEIPTS ARE DATED 7/11/21 AND 7/20/21. BECAUSE ONE OF THE RECEIPTS IS MORE THAN A YEAR OLD, ALL EXTINGUISHERS NEED TO BE INSPECTED AND TAGGED BY AN APPROVED FIRE PROTECTION COMPANY, AND THIS NEEDS TO BE DONE AN ANNUAL BASIS. *NOTE: THEFT OF EXTINGUISHERS HAS BEEN RECOGNIZED AS AN ONGOING ISSUE FOR THIS PROPERTY, AND BRIAN HAS BEEN INFORMED ON MULTIPLE OCCASIONS THAT HE HAS THE OPTION OF PROVIDED RESIDENTS WITH INDIVIDUAL EXTINGUISHERS THAT WOULD BE PLACED IN EVERY APARTMENT. BRIAN HAS REFUSED TO PROVIDE INDIVIDUAL EXTINGUISHERS TO RESIDENTS. SMOKE DETECTOR INSPECTION SHEET NEEDS TO BE FILLED OUT AND SIGNED. A REPORT WAS PROVIDED BY BRIAN, BUT NO DETAILS ARE INCLUDED ON THE REPORT AND IT IS NOT SIGNED. AN INSPECTION REPORT NEEDS TO BE PROVIDED FOR THE FIRE ALARM PULL STATIONS/LOCAL ALARMS THAT ARE ON THE PROPERTY. THIS REPORT NEEDS TO BE PROVIDED BY AN APPROVED FIRE PROTECTION COMPANY. VIOLATIONS ABATED FIRE SPRINKLER INSPECTION REPORT IS APPROVED. LOCKS ON FIRE DEPARTMENT RISER ROOM ARE APPROVED. THE BUILDINGS HAVE MULTIPLE BROKEN OR DAMAGED WINDOWS AND DOORS THE WALKWAYS AND STAIRWAY HAVE URINE, FECES AND DEBRIS ON ALL SURFACES, THERE IS REFUSE ON THE OFFICE BUILDINGS ROOF TOP GRANTED 30 DAT EXTENSION
05/31/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - HEARING CONTINUED TILL SEPT 13, 2022 AT 0830
05/18/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - NOTICE OF VIOLATION TO BE MAILED AND RECORDED
05/18/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - SECTION 8 INSPECTION COMPLETED 5-13-2022 REPORT SUBMITTED 5-17-2022
05/09/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - FOLLOW INSPECTION WITH GUARDS, THE BUILT UP POST WAS FINISHED WITHOUT A PERMIT OR STRUCTURAL ENGINEER.
05/06/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - EXTERIOR CODE VIOLATIONS, THERE ARE BROKEN WINDOWS, LOOSE AND DAMAGED DECK BOARDS, STAIRWELL GUARDS LOOSE AND DAMAGED. A BUILT UP POST AND ADDITIONAL MEMBERS WAS INSTALLED TO SUPPORT THE THIRD STORY WALKWAY THIS WORK WAS DONE WITHOUT A PERMIT. THIS WORK WILL REQUIRE A STRUCTURAL ENGINEERING AND BUILDING PERMIT. THE WALKWAYS WITH URINE, FECES AND DEBRIS ON ALL SURFACES. THERE ARE SPRINKLERS WITH PAINT OVER SPRAY, THERE ARE MISSING PORTABLE FIRE EXTINGUISHERS. THERE ARE ABANDON APPLIANCES, REFUSE AND SHOPPING CARTS THROUGH OUT THE PROPERTY. THE POOL IS EMPTY BUT HAS LITTER. THE SHADE STRUCTURE NEXT TO THE POOL IS IN DISREPAIR.
04/29/2022 COT - ENFC - Code Enforcement - Follow Up VALDEZ Approved Entered by VALDEZ - NIGHT INSPECTION WITH TPD , THERE ARE BROKEN, NON FUCTIONING LUMINARES IN ALL FLOORS AND STAIRWELLS
02/10/2022 COT - ENFC - Code Enforcement - Follow Up BERMUDEZ Approved Entered by BERMUDEZ - COURT FOLLOW ; NON COMPLIANCE,TOOK PICS FOR COURT.
09/03/2021 COT - ENFC - Code Enforcement - Follow Up BERMUDEZ Approved Entered by BERMUDEZ - ON SITE; TOOK PICTURES TO ISSUE COURT CITATION.