Case Details

Status:

COMPLIAN

Type:

FIRE AT COMMERCIAL BUILDING

Entered Date:

01/24/2021

Applicant:

SUJAM LLC

Description:

BUILDING FIRE EVENT NUMBER F210240191

Outstanding Inspections

Case Number: T21DV00364
Case Status: COMPLIAN
Case Description: FIRE AT COMMERCIAL BUILDING
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T21DV00364
Case Description: FIRE AT COMMERCIAL BUILDING
Total Completed Inspections - 1
End Date Description Inspector Results Comments
01/24/2021 INSP - INITIAL CODE ENFORCMENT BERMUDEZ Approved ON SITE WITH TPD, TFD AND SOUTHWEST GAS; EVENT NUMBER F210240191. ADDRESS: 743 W MIRACLE MILE OWNER/ OCCUPANT: SUJAM LLC/ JERRY JARIWALA ONSITE MGR CAUSE OF DAMAGE: HOTEL FIRE LOCATION OF DAMAGE: WEST SIDE OF DUPLEX BUILGING/UNIT 11 AND 12 BUILDING: THERE IS FIRE AND HEAVY SMOKE DAMAGE TO THE ENTIRE EXTERIOR REAR WEST BUILDING WALL, TO INCLUDE THE FACIA AND ROOF. UNIT 11 SUSTAINED FIRE DAMAGE TO BATHROOM WINDOW FRAME CAUING WINDOW TO BREAK AND IS MISSING. UNIT 11 INTERIOR BATHROOM WALL COVERINGS AND FIXTURES IN THE FIRE DAMAGE ZONE. ELECTRICAL: THE FIRE DAMAGE ZONE HAS MULTIPLE ELECTRICAL DEVICES IN CLOSE PROXIMITY TO FIRE, TO INCLUDE BUT NOT LIMITED TO EXTERIOR ELECTRICAL CONDUIT, INTERIOR LIGHT FIXTURES. POWER WAS TURNED OFF AT THE SERVICE PANEL. PLUMBING: GAS HOT WATER HEATER DAMAGED BY FIRE. MUST BE REPLACED. GAS WAS TURNED OFF. MECHANICAL: N/A REMARKS: UNITS 11 AND 12 ARE NOW CONDEMNED, PERMITS ARE REQUIRED FOR ALL REPAIRS, GAS WAS TURNED OFF AND TAGGED BY SOUTHWEST GAS FOR UNITS 11 AND 12. THE PROPERTY IS A MASTER METERED SYSTEM AND SOUTHWEST GAS WAS CLEARED THROUGH ACC TO TEST FOR LEAKS PRIOR TO RESERVICE. MANAGER TO SECURE UNITS 11 AND 12 DUE TO FORCED ENTRY BY TFD. TFD ALSO POURED AGENT SOLUTION TO BREAK DOWN FLAMABLE COMPONENTS OF GASOLINE AT REAR OF BUILDING THAT IGNITED THE HOT WATER HEATER BY WAY OF THE GAS PILOT.

Completed Activity Special Conditions

Case Description - FIRE AT COMMERCIAL BUILDING
Case Number - T21DV00364
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
01/26/2021 CONTACTED IN PERSON
01/26/2021 RED CROSS / PRIMAVERA
01/26/2021 NOTICE AND ORDER ISSUED
01/26/2021 VIOLATION CLOSED
01/26/2021 STRUCTURE SECURED BY ???
01/26/2021 CALLBACK

Documents

File Name Document Type  
2021-01-24-21-05-20_AATSC.JPG IMAGES VIEW
2021-01-24-21-04-35_AATSC.JPG IMAGES VIEW
2021-01-24-21-04-32_AATSC.JPG IMAGES VIEW
2021-01-24-21-04-27_AATSC.JPG IMAGES VIEW
2021-01-24-21-06-05_AATSC.JPG IMAGES VIEW
DAMAGE REPORT 743 W MIRACLE MILE.DOC IMAGES VIEW
CAMSCANNER 01-26-2021 17.03.PDF DOCUMENTS VIEW