Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T21DV00364

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
01/24/2021 INSP - INITIAL CODE ENFORCMENT Approved ON SITE WITH TPD, TFD AND SOUTHWEST GAS; EVENT NUMBER F210240191.
ADDRESS: 743 W MIRACLE MILE

OWNER/ OCCUPANT: SUJAM LLC/ JERRY JARIWALA ONSITE MGR

CAUSE OF DAMAGE: HOTEL FIRE

LOCATION OF DAMAGE: WEST SIDE OF DUPLEX BUILGING/UNIT 11 AND 12

BUILDING: THERE IS FIRE AND HEAVY SMOKE DAMAGE TO THE ENTIRE EXTERIOR REAR WEST BUILDING WALL, TO INCLUDE THE FACIA AND ROOF. UNIT 11 SUSTAINED FIRE DAMAGE TO BATHROOM WINDOW FRAME CAUING WINDOW TO BREAK AND IS MISSING. UNIT 11 INTERIOR BATHROOM WALL COVERINGS AND FIXTURES IN THE FIRE DAMAGE ZONE.

ELECTRICAL: THE FIRE DAMAGE ZONE HAS MULTIPLE ELECTRICAL DEVICES IN CLOSE PROXIMITY TO FIRE, TO INCLUDE BUT NOT LIMITED TO EXTERIOR ELECTRICAL CONDUIT, INTERIOR LIGHT FIXTURES. POWER WAS TURNED OFF AT THE SERVICE PANEL.

PLUMBING: GAS HOT WATER HEATER DAMAGED BY FIRE. MUST BE REPLACED. GAS WAS TURNED OFF.


MECHANICAL: N/A



REMARKS: UNITS 11 AND 12 ARE NOW CONDEMNED, PERMITS ARE REQUIRED FOR ALL REPAIRS, GAS WAS TURNED OFF AND TAGGED BY SOUTHWEST GAS FOR UNITS 11 AND 12. THE PROPERTY IS A MASTER METERED SYSTEM AND SOUTHWEST GAS WAS CLEARED THROUGH ACC TO TEST FOR LEAKS PRIOR TO RESERVICE. MANAGER TO SECURE UNITS 11 AND 12 DUE TO FORCED ENTRY BY TFD. TFD ALSO POURED AGENT SOLUTION TO BREAK DOWN FLAMABLE COMPONENTS OF GASOLINE AT REAR OF BUILDING THAT IGNITED THE HOT WATER HEATER BY WAY OF THE GAS PILOT.