Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL
Address:

Entered Date:

06/19/2020

Applicant:

KSW PROPERTIES LLC

Description:

WORK WITH OUT PERMITS

Outstanding Inspections

Case Number: T20DV04274
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV04274
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 1
End Date Description Inspector Results Comments
06/19/2020 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved ON SITE INSPECTION. THE PROPERTY CONSIST OF A DUPLEX WITH A DETACHED DWELLING. THERE ARE (3) 125 AMP MAIN DISCONNECTS LOCATED ON THE DUPLEX. THESE ALL IN ONE TYPE PANELS APPEAR TO BE CODE COMPLIANT. THE NEWLY INSTALLED FLEX CONDUIT RUNS APPEAR TO BE A PART OF THE PERMITTED ROOF MOUNTED HVAC INSTALL. ONE OF THE SERVICE RISERS IS MISSING A CLAMP UNDER THE EAVE AREA. THERE ARE MULTIPLE RUNS OF NON SHEATHED METALLIC CABLES UNDER THE EAVE. THE DUPLEX DOES HAVE (2) NEW FRAMED ATTACHED LAUNDRY ROOM ENCLOSURES. THE ROOMS APPEAR TO HAVE EXISTING WATER AND STAND PIPES, THERE ARE NEW RECEPTACLES AND ABS DRAIN WASTE PIPES CONNECTED TO EXISTING PIPING, BOTH OF THESE ROOMS DO NOT HAVE DRAIN WASTE VENTING. THE DETACHED DWELLING HAS A NEWLY INSTALLED 125 AMP PANEL. THIS PANEL DOES NOT HAVE A GROUNDING SYSTEM AND OTHER CODE VIOLATIONS. THE DWELLING ALSO HAS A ROOF MOUNTED MINI SPLIT UNIT. THERE IS A NEWLY ATTACHED FRAMED LAUNDRY ROOM WITH NEW DRAIN WASTE PIPING, NO VISIBLE VENTING. THERE IS NEW PEX WATER SUPPLY LINES HOT AND COLD, THERE IS ALSO NEW ELECTRICAL CONSISTING OF A 110V AND A 220V CIRCUITS. ALL OF THIS WORK IS NOT PERMITTED A STOP WORK ORDER ORDER 0 DAYS WAS POSTED ON SITE ALONG WITH A STOP WORK ORDER PLACARD. 30 DAYS TO OBTAIN PERMITS.PHOTOS LOADED IN ONBASE

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T20DV04274
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
06/19/2020 CONTACTED BY PHONE
06/19/2020 STOP WORK ORDER ISSUED
02/10/2021 VIOLATION CLOSED
07/21/2020 RESEARCH

Documents

File Name Document Type  
SCAN_0001.PDF DOCUMENTS VIEW
20200619_120526.JPG DOCUMENTS VIEW
20200619_120607.JPG DOCUMENTS VIEW
20200619_120715.JPG DOCUMENTS VIEW
20200619_120849.JPG DOCUMENTS VIEW
20200619_120949.JPG DOCUMENTS VIEW
20200619_121031.JPG DOCUMENTS VIEW
20200619_122104.JPG DOCUMENTS VIEW
20200619_122416.JPG DOCUMENTS VIEW
20200619_133213.JPG DOCUMENTS VIEW
20200619_133232.JPG DOCUMENTS VIEW
20200619_133245.JPG DOCUMENTS VIEW
20200619_140533.JPG DOCUMENTS VIEW
20200619_140615.JPG DOCUMENTS VIEW