Description:

COMMUNICATION CALLED THAT T.F.D. ON SITE WITH A GUTTER FIRE, F201490196

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV03728
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/28/2020 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Communication called that T.F.D. on site witha gutter fire. While getting ready the call was cancelled. Communication called back to respond to the fire due to was having an electrical issue with the fire. Arrived and the units were still on site and picking up. The fire investigator was on site checking for cause and found where a nail was near some wiring that was channeled in the wood framing. The stud was charred and the wiring was also burned in the area of the nail. The rain gutter was also charged and has some burning inside the wall framing at the roof area. The metal cap was removed due to removing the wood siding and the roofing material was pulled off to check for fire on the plywood. A vent hole was cut to check for fire in the rafter spacing. The fire was in the southwest bedroom on the door to the exterior. The wires were cut and taped up to have the electrical turned back on. The breakers were turned back on to both unit. The fire was contained to the rear wall in the southwest bedroom. Having trouble with the breaker to the rear unit on the main breaker for unit B. The breaker is hard to turn off and back on when required. Did let the owner know that an electrician will need to check the breaker and may need to be replaced. The owner signed the paperwork and will secure the area. Southwest Gas was leaving the gas on but has an issue with the dryer vent lacking a cap with louvers for the flex and was outside the house near the porch. RV.
06/17/2020 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved Stop by the property to check the progress of the damage being repaired. The owner was on site and showed areas damaged and nothing has been done to the fire damage due to still working with the insurance. They are still having problems with the electrical and the son is coming from Phoenix and check the breakers who is an electrician. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T20DV03728
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
05/28/2020 NOTICE OF VIOLATION ISSUED
05/28/2020 STRUCTURE SECURED BY ???