Case: T20DV03377
Case Details
Entered Date:
05/15/2020
Applicant:
ALVERNON APARTMENTS LLC
Description:
WATER HEATER FIRE
Outstanding Inspections
Case Number: T20DV03377
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| EMERGENCY CALL OUT | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T20DV03377
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2020 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | ALL DOCS AND PHOTOS IN ONBASE , CLOSE CASE |
| 05/15/2020 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | EMERGENCY CALL OUT BY TFD:N/A FROM THE VISUAL INSPECTION. TFD STATED ADJACENT UNIT WAS OK. ELECTRICAL: WATER HEATER ELEMENT HAS BURNED AND COMPONENTS ARE CHARRED. THE SUB PANEL HAS NO LABELING FOR A WATER HEATER. THE CONDUCTOR SIZE TO THE UNIT IS 14/3 AND ALL BREAKERS IN THE SUB PANEL ARE 20 AMPS. THE WATER HEATER DATA PLATE READS 4500 WATTS AT 240 VOLTS. ACCORDING TO THIS INFORMATION THE CIRCUIT IS UNDER SIZED, NOT RATED FOR THE CURRENT USE. PLUMBING: NA MECHANICAL: MILD SMOKE. REMARKS: THE UNIT IS CONDEMNED, POWER WAS DISCONNECTED BY TEP. MANAGEMENT WAS ALERTED TO THE FIRE VIA PHONE CONTACT. PERMIT IS REQUIRED FOR REPAIRS |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T20DV03377
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 05/15/2020 | CONTACTED BY PHONE |
| 05/15/2020 | CONTACTED IN PERSON |
| 05/15/2020 | NOTICE AND ORDER ISSUED |
| 05/15/2020 | VIOLATION CLOSED |
| 05/15/2020 | STRUCTURE SECURED BY ??? |
| 05/15/2020 | 8-5 CITY COMM EMERGENCY |