Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

RESIDENTIAL FIRE

Entered Date:

05/05/2020

Applicant:

DESERT SHORES ESTATES LLC, ATTN: SKYLINE REAL ESTATE

Description:

Fire at MH unit 1

Completed Inspections

Case Status: COMPLIAN
Case Number: T20DV03083
Case Description: RESIDENTIAL FIRE
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/05/2020 INSP - FOLLOW UP CODE ENFORCE GONZALEZ Approved CONFIRMED METER HAS BEEN REMOVED
05/05/2020 INSP - INITIAL CODE ENFORCMENT GONZALEZ Approved UPON ARRIVAL, TUCSON FIRE INVESTIGATORS ON SITE AT THE MOBILE HOME IDENTIFIED NUMBER ONE. AN ELECTRICAL CONDUCTOR FOR A WALL MOUNT A.C. UNIT ON THE SOUTH END WALL HAS BEEN DAMAGED BY FIRE. THE INTERIOR OF THE FIRE DAMAGED WALL, THERE IS A WEIGHT BEARING STUD THAT HAS BEEN CHARRED AND IN NEED OF REPLACEMENT. IT APPEARS THE TOP PLATE AND ROOF MEMBERS ABOVE THE CHARRED STUD WILL BE NEEDED TO BE EXPOSED AND EVALUATE THE EXTENT OF FIRE DAMAGE. THE EXPOSED NONMETALLIC ELECTRICAL CONDUCTORS THAT MELTED AND BLACKENED FROM THE FIRE, HAVE A NEWER DATE STAMP LABELED 2015. THERE ARE NON-CODE COMPLIANT ELECTRICAL CONNECTORS AND MODIFICATIONS THAT HAS BEEN INSTALLED INSIDE THE MOBILE HOME UNIT. THE INTERIOR DOWNSTREAM PANEL HAVE NEWER ELECTRICAL CONDUCTORS AND IS APPROX. 3-4 FEET FROM THE UNIT'S FLOOR. WINDOW SIZING HAS BEEN ALTERED AND DOOR OPENINGS HAS BEEN SEALED CLOSED MODIFYING THE MOBILE HOME'S FLOOR PLAN, EGRESS AND STRUCTURAL INTEGRITY. THE PRIVATELY OWNED ELECTRICAL METERING DEVICE IS UNSTABLE AND NOT PROPERLY ANCHORED TO THE PEDESTAL. THE MOBILE HOME MANAGEMENT HAS REMOVED THE PRIVATELY OWNED METER AND INSTALLED A PLATE TO PREVENT THE UNIT TO BE RE-CONNECTED WITHOUT PROPER REPAIRS MADE UNDER A PERMIT. NO PERMITS HAVE BEEN FOUND FOR THE ELECTRICAL OR STRUCTURAL MODIFICATIONS TO THIS UNIT. ACCORDING TO AERIALS THE UNIT HAS BEEN INSTALLED AT SPACE LABELED ONE PRIOR TO 2014. POSTED UNFIT TO OCCUPY PLACARD AT THE WINDOW FACING WEST TOWARDS THE STREET ENTRANCE OF THE MOBILE HOME PARK.

Completed Activity Special Conditions

Case Description - RESIDENTIAL FIRE
Case Number - T20DV03083
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
05/06/2020 CONTACTED BY PHONE
05/06/2020 CONTACTED IN PERSON
01/25/2022 CONTACTED BY EMAIL
05/06/2020 NOTICE AND ORDER ISSUED
05/06/2020 VIOLATION CLOSED

Documents

File Name Document Type  
2020-05-05-11-15-57_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-13-57_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-14-01_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-14-19_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-14-22_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-16-01_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-16-05_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-18-02_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-18-09_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-18-47_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-18-52_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-19-21_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-19-30_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-20-05_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-20-44_AATSC.JPG DOCUMENTS VIEW
2020-05-05-11-21-28_AATSC.JPG DOCUMENTS VIEW
2020-06-01-10-17-10_AATSC.JPEG DOCUMENTS VIEW