Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Inspection Status: Approved

Inspection History: INSP - INITIAL CODE ENFORCMENT

Case Number - T20DV03083

Inspection Description - INSP - INITIAL CODE ENFORCMENT

Inspection Status - Approved

Date Description Inspector Results Comments
05/05/2020 INSP - INITIAL CODE ENFORCMENT Approved UPON ARRIVAL, TUCSON FIRE INVESTIGATORS ON SITE AT THE MOBILE HOME IDENTIFIED NUMBER ONE. AN ELECTRICAL CONDUCTOR FOR A WALL MOUNT A.C. UNIT ON THE SOUTH END WALL HAS BEEN DAMAGED BY FIRE. THE INTERIOR OF THE FIRE DAMAGED WALL, THERE IS A WEIGHT BEARING STUD THAT HAS BEEN CHARRED AND IN NEED OF REPLACEMENT. IT APPEARS THE TOP PLATE AND ROOF MEMBERS ABOVE THE CHARRED STUD WILL BE NEEDED TO BE EXPOSED AND EVALUATE THE EXTENT OF FIRE DAMAGE. THE EXPOSED NONMETALLIC ELECTRICAL CONDUCTORS THAT MELTED AND BLACKENED FROM THE FIRE, HAVE A NEWER DATE STAMP LABELED 2015. THERE ARE NON-CODE COMPLIANT ELECTRICAL CONNECTORS AND MODIFICATIONS THAT HAS BEEN INSTALLED INSIDE THE MOBILE HOME UNIT. THE INTERIOR DOWNSTREAM PANEL HAVE NEWER ELECTRICAL CONDUCTORS AND IS APPROX. 3-4 FEET FROM THE UNIT'S FLOOR. WINDOW SIZING HAS BEEN ALTERED AND DOOR OPENINGS HAS BEEN SEALED CLOSED MODIFYING THE MOBILE HOME'S FLOOR PLAN, EGRESS AND STRUCTURAL INTEGRITY. THE PRIVATELY OWNED ELECTRICAL METERING DEVICE IS UNSTABLE AND NOT PROPERLY ANCHORED TO THE PEDESTAL. THE MOBILE HOME MANAGEMENT HAS REMOVED THE PRIVATELY OWNED METER AND INSTALLED A PLATE TO PREVENT THE UNIT TO BE RE-CONNECTED WITHOUT PROPER REPAIRS MADE UNDER A PERMIT. NO PERMITS HAVE BEEN FOUND FOR THE ELECTRICAL OR STRUCTURAL MODIFICATIONS TO THIS UNIT. ACCORDING TO AERIALS THE UNIT HAS BEEN INSTALLED AT SPACE LABELED ONE PRIOR TO 2014. POSTED UNFIT TO OCCUPY PLACARD AT THE WINDOW FACING WEST TOWARDS THE STREET ENTRANCE OF THE MOBILE HOME PARK.