Case: T19DV04350
Case Details
Entered Date:
05/30/2019
Applicant:
KMS ENTERPRISES
Description:
ECLOSED CARPORT TURNED INTO A ROOM WITHOUT PERMITS
Case Violations
Case Number: T19DV04350
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Violations: 2
| Violation Date | Code Statue |
|---|---|
| 07/01/2019 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 01/19/2021 | CITATION ISSUED |
Completed Inspections
Case Status: COMPLIAN
Case Number: T19DV04350
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 3
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/27/2019 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | The supervisor Martin Romero called that inspector Morales is at a site with work with out permits on a house and needs to be looked at for permit issues. Arrived and the worker were on site and was able to walk around with them and look at the work being done. The front porch and the carport and with a storage room has all been re-done on the roof sheathing and the rafters. The existing has been removed and re-built with new wood framing The wood siding has all been replaced through out the storage room area. The cooler has been removed from the roof and have stated that AC package unit will be place on the roof. The beams on the front porch and the carport are 2-2 x 6 split on a 4 x 4 wood post. The rafters are 2 x 6's on 24" o.c. spanning approx. 9'. The rafters are not bearing on the top plate at this time and went over if the 2 x 6's are to remain, will need to place some blocking placing under the 2 x 6's to have the proper bearing for support of the new porch. The drywall has been remove at the bottom from the floor up approx. 4' up due to water damage. Other rooms have more drywall above the 48" removed including some of the ceilings. The front of the house by the front door has all new wood siding near the living room area. New windows have been replaced with new through out. There is a hole made in the concrete in the bathroom area and dug out to the main drain line. The pipe has a crack and needs to be replaced. The workers stated that the Permaliner may be installed. Did talk to the owner and went over the issues that require permits. The front door was removed and the workers were advised that the door installation can be completed to have the house secured and not to cover any work from the point and not to continue any more work on the property until the permit has been issued or the approval has been issued. Will do N.O.V. RV. |
| 06/27/2019 | INSP - INITIAL CODE ENFORCMENT | MORALES | Approved | ON SITE WITH RV, SPOKE TO OWNER ON THE PHONE AND WORKERS ON SITE. |
| 12/11/2020 | INSP - FOLLOW UP CODE ENFORCE | MORALES | Approved | ON SITE AT PROPERTY VIOLATIONS REMAIN |
Completed Activity Special Conditions
Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T19DV04350
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
| Date | Name |
| 03/12/2021 | CONTACTED BY PHONE |
| 10/11/2019 | RETURNED MAIL |
| 07/01/2019 | CONTACTED BY MAILING |
| 07/01/2019 | NOTICE OF VIOLATION ISSUED |
| 01/19/2021 | LONG FORM CITATION |