Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

05/28/2019

Applicant:

EM-CAR LLC

Description:

DRUMS IN BACK OF BUILDING CAUGHT FIRE

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV04298
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/28/2019 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Communication called that T.F.D. on site with metal drums that caught fire in the rear of the building. Arrived and the units were still on site and checking for hot spots. A pump was being cleaned with a solvent and was in a contained area near a boiler that was on gas. Appears that the vapors enter the boiler room area through a vent at the bottom and a flash fire happened. A glass window was broken that goes to the office, some copper lines for nitro that went to a mixing box, an air line of copper lost the plug and was re-capped, a mini split system was damaged by the fire and will need to be replaced, has conduit on the wall that has heat damage and apart, a metal door was rusted at the bottom and was still burning in the middle of the door and was wet with a hose on site. Southwest Gas was called to the site due to the boiler has gas and the gas line was checked. Did find gas leaks on the roof and those leaks were sealed by Southwest Gas while on site. The gas was being turned back on. The owner was on site and signed the N.O.V. and went over that a permit will be required for the repairs to be done by a contractor. The operation that was being done at the time of the fire was not an approved method for the area to be done. The fire inspector will be checking the area. Once the gas being turned back on and the building was locked up. The business is able to continue to do business and had an operation in process during the fire and was able to complete the operation on a machine. I left the site. RV.
08/07/2020 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved All issues have been addressed on the property and the procedure has been changed that caused the fire in the area. The area has been cleaned and the piping that was damaged in the fire has been replaced or repaired. All is working in the area at this time. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T19DV04298
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
05/28/2019 NOTICE OF VIOLATION ISSUED
05/28/2019 STRUCTURE SECURED BY ???