Status:

COMPLIAN

Type:

MULTIPLE TYPES
Address:

Entered Date:

02/01/2019

Applicant:

WHEELRITE ENTERPRISES LLC ATTN: JOEL T KOLOSICK

Description:

FURNACE ROOM LEAKS WHEN IT RAINS. WIRING MAY BE FAULTY. DUCTWORK IN FURNACE MAY NOT BE UP TO CODE. DUCT TAPE IS FRAYED

Case Violations

Case Number: T19DV00597
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 4
Violation Date Code Statue
05/15/2019 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
05/17/2019 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
05/17/2019 T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly.
05/17/2019 T.C. Ch. 16, Sec. 16-11(g) INTERIOR SANITATION. (1) The interior of every building or structure shall be maintained free from any unsafe or unsanitary accumulation of refuse. (2) All sanitary facilities shall be installed and maintained in a safe and sanitary condition. (3) Every dwelling unit must have a kitchen, which shall include a sink. Sink drain boards and countertops adjacent to the kitchen sink shall be made of non-absorbent materials, or must be covered by a non-absorbent material.

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV00597
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
05/15/2019 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved ON SITE INSPECTION: FRONT DOOR IS MISSING WEATHER STRIPING AND THRESHOLD. THE COOLER HIGH SWITCH IS INOPERABLE. THERE ARE NO SMOKE ALARMS IN THE DWELLING. THE INTERIOR PANEL IS NOT LABELED. THE FURNACE COMPARTMENT HAS OPEN PENETRATIONS, LIGHT FIXTURE WITH NO OFF AND ON SWITCH. THERE IS DEBRIS IN THE COMPARTMENT AND THE AIR RETURN CHAMBER. THE GAS FIRED WATER HEATER VENTILATION EXHAUST GAS PIPE AND THE ELECTRICAL METALLIC TUBING RUN IN THE SAME CHASE. FIRE STOPPING REQUIRED INSIDE THE FURNACE COMPARTMENT.
07/09/2019 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved ALL VIOLATIONS ABATED CLOSE CASE

Outstanding Case Activity Conditions

Date Name Approved
05/17/2019 2018 INTERNATIONAL BUILDING CODE CHAPTER 7 FIRE AND SMOKE PROTECTION SECTION 712 VERTICAL OPENINGS SECTION 714 OPENED PENETRATIONS Not Approved

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T19DV00597
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
05/15/2019 CONTACTED BY PHONE
05/17/2019 CONTACTED BY MAILING
05/17/2019 CONTACTED BY EMAIL
07/09/2019 VIOLATION CLOSED