Inspection History Details
Inspection Status: Approved
Inspection History: INSP - INITIAL CODE ENFORCMENT
Case Number - T19DV00597
Inspection Description - INSP - INITIAL CODE ENFORCMENT
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 05/15/2019 | INSP - INITIAL CODE ENFORCMENT | Approved | ON SITE INSPECTION: FRONT DOOR IS MISSING WEATHER STRIPING AND THRESHOLD. THE COOLER HIGH SWITCH IS INOPERABLE. THERE ARE NO SMOKE ALARMS IN THE DWELLING. THE INTERIOR PANEL IS NOT LABELED. THE FURNACE COMPARTMENT HAS OPEN PENETRATIONS, LIGHT FIXTURE WITH NO OFF AND ON SWITCH. THERE IS DEBRIS IN THE COMPARTMENT AND THE AIR RETURN CHAMBER. THE GAS FIRED WATER HEATER VENTILATION EXHAUST GAS PIPE AND THE ELECTRICAL METALLIC TUBING RUN IN THE SAME CHASE. FIRE STOPPING REQUIRED INSIDE THE FURNACE COMPARTMENT. |