Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

01/31/2019

Applicant:

BLUE RIBBON 1141 N CATALINA AVE LLC

Description:

WALL WITHIN APARTMENT FELL IN

Case Violations

Case Number: T19DV00540
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 4
Violation Date Code Statue
01/31/2019 REFERENCE
01/31/2019 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
01/31/2019 T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (3) The building, structure or any portion thereof has been damaged by fire, earthquake, wind, flood or any other cause, to such an extent that the structural strength or stability thereof is materially less than it was before the damage and is less than the minimum requirements of the building code for new buildings of similar structure, purpose or location.
01/31/2019 T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (5) The building, structure, or any portion or member or appurtenance thereof is likely to fail, or to become detached or dislodged, or to partially or completely collapse and thereby injure persons or damage property.

Outstanding Inspections

Case Number: T19DV00540
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 4
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
EMERGENCY CALL OUT None Not Inspected
NPO(EL)-WIRING/SWITCH/OUTLT/FX None Not Inspected
NPO(DL)-DILAPIDATED STRUCTURE None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T19DV00540
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date Description Inspector Results Comments
01/31/2019 INSP - INITIAL CODE ENFORCMENT MENDOZA Approved BUILDING DEMOLITION TAKING PLACE ON A PROPERTY DIRECTLY SOUTH. DURING DEMO THE CMU WALL BUCKLED OUTWARD TOWARDS THE RESIDENTIAL UNIT COLLAPSING THE PERIMETER WALL AND IMPACTING THE ROOF AND CMU WALL OF THE RESIDENTIAL STRUCTURE. PORTION OF THE ROOF SHEATHING IS DAMAGED AS WELL AS THE FACIA DISLODGED, ALLTHOUGH DAMAGE TO THE ROOF IS NOT SEVERE. THE IMPACT ON THE RESIDENTIAL STRUCTURE WALL CAUSED A HOLE APPROX. 3'X4' NEAR THE SOUTH WEST CORNER OF THE WALL AND CAUSING CRACKING AND HEAVY SEPERATION THROUGHOUT THE SOUTHWEST PORTION OF THE STRUCTURE. . IMPACT WITH THE RESIDENTIAL STRUCTURE WAS ALONG APPROX HALF OF THE SOUTHERN WALL. THE MATERIAL REMAINS UP AGAINST THE RESIDENTIAL STRUCTURE. STUCCO DAMAGE ON THE EXTERIOR FINISH. ONE ELECTRICAL CIRCUIT AFFECTED. CIRCUIT WAS ISOLATED AND SECURED. IT SHALL REMAIN OFF UNTIL REPAIRS CAN BE MADE. A STRUCTUAL ENGINEER SHALL EVALUATE THE DAMAGE AND STRUCTUAL INTEGRITY OF THE WALL FOR THE PURPOSE OF SECUREMENT AND REPAIR, UNDER PERMIT CONCORD GENERAL CONTRACTOR ON SITE HAS SECURED THE DEMO AREA UNTIL THE ENGINEER CAN EVALUATE. CONTRACTOR WORKING WITH THE TENANT AND OWNER FOR ACCESS FOR SECUREMENT AND REPAIRS

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T19DV00540
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 5
Date Name
01/31/2019 CONTACTED BY MAILING
01/31/2019 CONTACTED BY EMAIL
01/31/2019 NOTICE OF VIOLATION ISSUED
02/25/2019 VIOLATION CLOSED
02/25/2019 RESEARCH

Documents

File Name Document Type  
IMG_20190131_102849.JPG IMAGES VIEW
IMG_20190131_102914.JPG IMAGES VIEW
IMG_20190131_102922.JPG IMAGES VIEW
IMG_20190131_110208.JPG IMAGES VIEW
IMG_20190131_110214.JPG IMAGES VIEW
IMG_20190131_111224.JPG IMAGES VIEW
IMG_20190131_111240.JPG IMAGES VIEW
IMG_20190131_111249.JPG IMAGES VIEW
IMG_20190131_111256.JPG IMAGES VIEW
IMG_20190131_111347.JPG IMAGES VIEW