Case: T19DV00206
Case Details
Entered Date:
01/11/2019
Applicant:
WENDELLE A ROSE
Description:
ROOF LEAKS WHEN IT RAINS IN BED ROOM AND LIVING ROOM AREAS ROOF SWELLING UP IN BEDROOM AREA. WATER HEATER NOT FUNCTIONING PROPERTY
Case Violations
Case Number: T19DV00206
Case Status: COURTCMP
Case Description: RES: MINIMUM HOUSING
Total Violations: 7
| Violation Date | Code Statue |
|---|---|
| 02/05/2019 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 02/05/2019 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 02/05/2019 | T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability. |
| 02/05/2019 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
| 02/05/2019 | T.C. Ch. 16, Sec. 16-11(f)(3) Every floor and floor support shall be maintained in a safe and structurally sound condition, and every existing floor covering shall be maintained in safe condition that is free of defect or deterioration that creates an unsafe or unsanitary condition. |
| 02/05/2019 | T.C. Ch. 16, Sec. 16-11(b) (3) VENTILATION. b. Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room. |
| 02/05/2019 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
Completed Inspections
Case Status: COURTCMP
Case Number: T19DV00206
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 02/01/2019 | INSP - INITIAL CODE ENFORCMENT | VALDEZ | Approved | ON SITE INSPECTION RESULTS: THE CEILING'S DRYWALL IS DAMAGE FROM A ROOF LEAKS IN THE LIVING ROOM AND BED ROOM AREA. THERE ARE NO SMOKE DETECTORS IN THE BEDROOMS, KITCHEN OUTLET HAS MISSING COVER PLATE AND ALSO MISSING FLOOR TILE PIECE. THE BATHROOM FAN IS INOPERABLE AND PENETRATIONS UNDER THE SINK ARE NOT SEALED. THE ROOF COVERING IS ASPHALTS SHINGLES WITH MULTIPLE REPAIR SPOTS. THE ROOF COVERING IS IN A DETERIORATE STATE. THE SHINGLES ARE BRITTLE AND DAMAGE IN MULTIPLE AREAS OF THE ROOF. THE ROOF VALLEY HAS MULTIPLE CRACKS IN THE PATCH AREA. THE EDGE OF THE ROOF ALSO HAS SIGNS OF DETERIORATION WITH DAMAGED OR MISSING SHINGLES. THE CEILING OF THE ABOVE ADDRESS HAS SIGNS OF THE WATER INTRUSION WATER DAMAGE. THE PATCHWORK HAS FAILED. TWO OF THE THREE COOLER HAVE SEVER RUST DAMAGE TO INCLUDE ONE COOLER STAND. THE COOLER ELECTRICAL ENCLOSURE HAS A MISSING THE COVER AND INTERNAL COMPONENTS ARE UNSECURED AND EXPOSED. THE OTHER TWO ROOF MOUNTED COOLER OUTLETS ARE NOT PROTECTED AND EXPOSED. THE ELECTRICAL METAL TUBULAR CONDUCT ENTERS THE ROOF AIR INLET. NOTE THE GAS SUPPLY IS OFF. |
| 10/28/2020 | INSP - FOLLOW UP CODE ENFORCE | VALDEZ | Approved | CIVIL MOTION SIGNED BY THE JUDGE CLOSE CASE |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T19DV00206
Case Status: COURTCMP
Total Completed Case Activity Conditions: 7
| Date | Name |
| 02/01/2019 | CONTACTED BY PHONE |
| 07/15/2019 | CONTACTED BY MAILING |
| 08/20/2019 | CONTACTED BY EMAIL |
| 07/25/2019 | CERTIFIED RECEIPT CARD |
| 07/15/2019 | CITATION ISSUED |
| 10/21/2020 | VIOLATION CLOSED |
| 07/15/2019 | COURT HEARING INFO |