Inspection History Details
Inspection Status: Approved
Inspection History: INSP - FOLLOW UP CODE ENFORCE
Case Number - T19DV00206
Inspection Description - INSP - FOLLOW UP CODE ENFORCE
Inspection Status - Approved
| Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 10/28/2020 | INSP - FOLLOW UP CODE ENFORCE | Approved | CIVIL MOTION SIGNED BY THE JUDGE CLOSE CASE | |
| 10/16/2020 | INSP - FOLLOW UP CODE ENFORCE | Approved | ON SITE THE ROOF COVERING IS COMPLETE. THE UNIT 2620 IS VACANT. WILL EMAIL OWNER ON REPAIRS | |
| 10/16/2020 | INSP - FOLLOW UP CODE ENFORCE | Approved | SUBMITTED CIVIL MOTION FOR DISMISSAL TO M.A. | |
| 06/23/2020 | INSP - FOLLOW UP CODE ENFORCE | Approved | ON SITE COURT INSPECTION, THE ROOF IS COVERED WITH FELT PAPER. ROOFER ONSITE IN UNMARKED VEHICLES. ROOFERS STATED THEY REPLACED 90 PERCENT OF THE DECKING AND REPAIRED THE DAMAGED EAVE AREA, ROOF SIZE IS ESTIMATED AT 4000 SQUARE FEET. ROOFERS STATED THEY REMOVED 5 ROOF LAYERS. THIS WORK TO REMOVE THE MULTIPLE ROOFS AND RE SHEATH THE ROOF TOOK 3 DAYS. THE ROOFER SHOWED ME A VIDEO OF THE ENTIRE ROOF WITH NEW SHEATHING, I ESTIMATE OVER 90 PERCENT OF THE PLYWOOD WAS REPLACED. I WALKED AROUND THE TRI PLEX AND THERE WERE SOME AREAS WITH EXISTING PLYWOOD BUT MOST OF ALL THE SHEATHING WAS NEW. THE DAMAGED EXTENDED ROOF AREA WAS REMOVED NOW THIS AREA MATCH'S THE EXISTING EAVE AREA. THE ELECTRICAL OUTLET ON THE ROOF HAVE EXPOSED WIRING, UNPROTECTED, UNABLE TO INSPECT THE UNIT 2620 INTERIOR, OWNER STATED THOSE REPAIRS WILL BE DONE ONCE THE ROOF IS REPAIRED. ADVISE OWNER TO HAVE ROOFING CONTRACTOR OBTAIN THE PERMIT AND PROTECT THE ROOF MOUNT ELECTRICAL AND CONTINUE WITH REQUIRED REPAIRS. | |
| 02/07/2020 | INSP - FOLLOW UP CODE ENFORCE | Approved | ONSITE INSPECTION: THERE HAVE BEEN NO REPAIRS OR PERMITS IN ISSUED STATUS. THE TWO REAR UNITS ARE VACANT THE FRONT UNIT IS OCCUPIED | |
| 07/09/2019 | INSP - FOLLOW UP CODE ENFORCE | Approved | ON SITE INSPECTION UNIT 2620 IS VACANT NO INTERIOR REPAIRS HAVE BEEN DONE. THE ROOF IS BEING COVERED ON THE NORTH AND EAST SIDE WITH SHINGLES BEING APPLIED OVER THE DAMAGED ROOF COVERING. THERE ARE NAIL HEADS NAILED ON TOP OF THE SHINGLES. TWO COOLERS HAVE BEEN REMOVED THE DOWN DRAFT DUCT WORK IS NOT PROTECTED, ELECTRICAL ROOF MOUNTED OUTLET ARE ALSO NOT PROTECTED. ROOF DECKING WAS REPLACED IN THE EAVE AREA AND INCORRECTLY INSTALLED, A SECTION OF THE ROOF DECKING IS NOT NAILED TO THE RAFTER TAILS. A PERMIT IS NOW REQUIRED FOR THE ROOF REPAIR. NEW WATER HEATER WAS INSTALLED, WILL CITE |