Case: T18DV07818
Case Details
Entered Date:
12/03/2018
Applicant:
SEDONA SPRINGS AZ LLC ATTN: DASMEN RESIDENTIAL
Description:
NO HEAT SINCE OCTOBER. SPACE HEATER GIVEN AS AN ALTERNATIVE PORCH BEAMS ROTTED AND UNSAFE HOLE IN BEDROOM CIELING WATER LEAKS THROUGH TO CLOSET YELLOW WATER STAINS PRESENT LEAKY WINDOWS CARBON MONOXIDE ALARMS WENT OFF LAST NIGHT
Case Violations
Case Number: T18DV07818
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 5
Violation Date | Code Statue |
---|---|
12/06/2018 | REFERENCE |
12/06/2018 | T.C. Ch. 16, Sec. 16-11(f)(2) Every ceiling, roof, and ceiling and roof support must be sufficient to carry imposed loads safely, and must not buckle, sag or split due to defective material or deterioration. |
12/06/2018 | T.C. Ch. 16, Sec. 16-11(f)(5) All interior coverings, finishes, surfaces including walls, ceilings and floors shall be maintained in a good, clean and sanitary condition. Peeling, chipping, flaking or abraded paint shall be repaired, removed or covered. All walls, ceilings or floors shall be free from holes, breaks and loose or rotting materials. Cracked or loose plaster, wallboard, decayed wood or other defective surface conditions shall be corrected. |
12/06/2018 | T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element. |
12/06/2018 | T.C. Ch. 16, Sec. 16-12(c) STAIRWAYS, DECKS AND PORCHES. All stairways, decks and porches shall be maintained in a safe condition and shall be capable of supporting the load and resisting all forces placed thereon by normal use. Every handrail and guardrail shall be firmly fastened and capable of supporting normally imposed loads, and shall be maintained in good condition. |
Outstanding Inspections
Case Number: T18DV07818
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
NPO - EXT. BUILDING MAINTENANC | None | Not Inspected | ||
NPO - INT. BUILDING MAINTENANC | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV07818
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 2
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
12/06/2018 | INSP - INITIAL CODE ENFORCMENT | MENDOZA | Approved | SMALL HOLE AND WATER DAMAGE IN THE BEDROOM CLOSET CEILING DECK PLANKS ARE DILAPIDATED. SHOWS WOOD ROT, WATER DAMAGE. HEAVY FLEXING WHEN WALKING ON THEM. WOODEN PLATE PLACED OVER AN AREA THAT HAS HEAVY DILAPIDATION HOT WATER AND HEATING WAS OPERATIONAL AT THE TIME OF INSPECTION |
12/06/2018 | INSP - FOLLOW UP CODE ENFORCE | MENDOZA | Approved | MET WITH MANAGER AND MAINTENANCE. INSPECTED INTERIOR ROOF TRUSSES AND SAW NO WATER DAMAGE OR DETERIORATION. OK TO REPAIR CEILING DRYWALL. |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T18DV07818
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date | Name |
12/19/2018 | CONTACTED BY PHONE |
12/06/2018 | NOTICE OF VIOLATION ISSUED |
01/31/2019 | VIOLATION CLOSED |