Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

08/15/2018

Applicant:

GREGORIO VIZCARRA

Description:

COMMUNICATION CALLED THAT T.F.D. ON SITE WITH A MOBILE HOME FIRE, F182270032

Completed Inspections

Case Status: COMPLIAN
Case Number: T18DV04824
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/15/2018 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Communication called that T.F.D. on site with a mobile home fire. Arrived and the unit was still on site and had the smell of electrical burning in the washroom. The was a dryer outlet that was exposed from the box, a washer machine, electric water heater that has been changed from gas to electric. The main electrical panel for the mobile home has been replaced with new and does not have the proper access or clearance where installed. There is no damage to the mobile home but does have the smell of burning and not able to locate where the smell is coming from. When the fire units arrived. there was smoke in the room and that is gone at this time. The main breaker at the pedistal is going to remain off until the permit has been issued and the work has been done by a license contractor. Did meet with management and the meter will be blanked to not allow power to the mobile home once the work has been completed and the mobile home checked through out for electrical issues. The water heater is setting in water on the pan for the water heater and not draining water or set up for the drainage of the water from the pan to the exterior. The owner of the mobile home will lock up once they are done getting items they need for the day and will be staying with family. RV.
10/24/2018 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved The permit for the water heater has been issued, T18CM08150 on 10-11-18 and finaled on 10-12-18. Nothing on the electrical and called the owner to check and she will check on getting the permit. She call the electrical contractor to check if they will get the permit. Will check in 14 days. RV.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T18DV04824
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 3
Date Name
08/15/2018 NOTICE OF VIOLATION ISSUED
02/09/2019 VIOLATION CLOSED
08/15/2018 STRUCTURE SECURED BY ???