Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

07/09/2018

Applicant:

MI CASITA APARTMENTS

Description:

UNIT 210 PLUMBING PROBLEMS, ROACH/MICE INFESTATION (THIS AND OTHER UNITS) FAN ABOVE STOVE CARRODED

Case Violations

Case Number: T18DV03943
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 6
Violation Date Code Statue
07/11/2018 T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson.
07/11/2018 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.
07/11/2018 T.C. Ch. 16, Sec. 16-11(e) PLUMBING SYSTEMS. (3) All plumbing systems are to be maintained safe and hazard free and in a state of good repair. Every dwelling or dwelling unit shall have an adequate potable water supply. Every plumbing fixture, water and waste-pipe, and gas connection shall be properly installed in accordance with all applicable laws and maintained in good and sanitary working condition so as to prevent structural deterioration or health hazards, and are to be free from leaks and obstructions.
07/11/2018 T.C. Ch. 16, Sec. 16-11(f)(4) Every interior door, cabinet, and other feature shall be maintained in a safe and structurally sound condition.
07/11/2018 T.C. Ch. 16, Sec. 16-11(d) MECHANICAL EQUIPMENT. All mechanical equipment and appliances shall be properly installed, maintained in a safe, working, operating condition, and shall be free of any defect that impairs operability.
07/11/2018 T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons.

Completed Inspections

Case Status: COMPLIAN
Case Number: T18DV03943
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
07/10/2018 INSP - INITIAL CODE ENFORCMENT VIDAL Approved Met with the tenant and did an inspection on the unit. Found a water heater leaking on the bottom, a new gas furnace, shower valves leaking, toilet handle loose and not flushing properly, bedroom closet doors off track, smoke detectors not working or missing, exhaust fan has been removed and lacking the grill to cover the opening, GFCI lacking in the kitchen area, pocket door in living room off track, rats, roaches, and bed bugs. Has no management on site and was sent to the apartment complex next door. Did talk to the manager and they have taken over the building next door and this building. They have been on the property for a month. Will do N.O.V. RV.
08/27/2018 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved Met with the manager and the permit has not been purchased. The water heater has not been installed completely. The manager will call when all is ready due to want to rent the unit out. Will check in 10 days. RV.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T18DV03943
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
07/11/2018 CONTACTED BY MAILING
07/11/2018 NOTICE OF VIOLATION ISSUED