Case Details

Status:

COMPLIAN

Type:

WORK WITHOUT PERMITS-RESIDENTL

Entered Date:

06/19/2018

Applicant:

GWJ LEGACY REALTY LLC ATTN: BERNADETTE JABLONSKI

Description:

WORK WITH OUT PERMITS ELECTRICAL

Case Violations

Case Number: T18DV03568
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Violations: 1
Violation Date Code Statue
06/19/2018 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Outstanding Inspections

Case Number: T18DV03568
Case Status: COMPLIAN
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Outstanding Inspections - 1
End Date Description Inspector Results Comments
NPO(EL)-MAIN/PANEL/SUB/DISCONT None Not Inspected

Completed Inspections

Case Status: COMPLIAN
Case Number: T18DV03568
Case Description: WORK WITHOUT PERMITS-RESIDENTL
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/19/2018 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved THE MAIN SERVICE DISCONNECT (ALL IN ONE (A)) HAS NON CODE COMPLIANT MODIFICATIONS DONE TO THE UNIT. ALL OF THE INTERIOR COMPONENTS HAVE BEEN REMOVED WHICH IS A VIOLATION OF THE MANUFACTURES IS LISTING. THERE ARE FEEDERS FROM THIS SERVICE THAT RUNS TO THE ADJACENT PANEL WHICH IS AN OTHER ALL IN ONE SERVICE DISCONNECT (ALL IN ONE (B)) WITH A BLANK COVER AT THE METER SOCKET. THE FEEDERS ENTER THE BOTTOM THE PANEL (B) ON THE INTERIOR OF THE PREMISE SIDE AND THEN THEY ENTER THE UTILITY SIDE UNPROTECTED BY WAY OF THE SIDE WALL UP INTO THE METER SOCKET. THERE ARE ENERGIZED FEEDERS ON THE PREMISE SIDE OF THE PANEL. THE OVERHEAD FEEDERS FROM THE SECONDARY RISER RUN OVER THE TOP OF THE ROOF AND ARE NOT CODE COMPLAINT. THESE FEEDERS FEED A PANEL MOUNTED ON A DETACHED QUAD PLEX. THIS MODIFICATION IS NOT SAFE AND NOT CODE COMPLIANT, TEP DID SECURE THE PREMISE SIDE OF THE MAIN DISCONNECT (A).
11/07/2018 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved PERMIT IN GOOD STANDING AND EXPIRES ON 4/02/2019 CLOSE CASE

Completed Activity Special Conditions

Case Description - WORK WITHOUT PERMITS-RESIDENTL
Case Number - T18DV03568
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
Date Name
06/19/2018 CONTACTED BY PHONE
06/19/2018 CONTACTED IN PERSON