Case: T18DV03371
Case Details
Entered Date:
06/12/2018
Applicant:
H&M VENTURES LLC
Description:
mice infestation, cooler not working, leak in the roof.
Case Violations
Case Number: T18DV03371
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Violations: 9
| Violation Date | Code Statue |
|---|---|
| 06/20/2018 | REFERENCE |
| 06/20/2018 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 06/20/2018 | T.C. Ch. 16, Sec. 16-11(b) (2) COOLING. Every dwelling unit, guest room, and congregate residence shall be provided, in at least one habitable room, with either mechanical cooling or an alternate cooling method. Cooling facilities shall be installed and maintained in a safe condition and in accordance with the manufacturer's recommendations, and shall be capable of providing adequate cooling, appropriate for the climate, to assure a safe living environment. Evaporative cooling shall be maintained to be free of excessive rust, corrosion or mineral deposits that limit proper operation. Any mounting apparatus for a cooling facility must be structurally sound. Mechanical fans or portable evaporative cooling devices may only be used on a temporary basis as the sole source of cooling when the permanent cooling system is being repaired or replaced. |
| 06/20/2018 | T.C. Ch. 16, Sec. 16-11(b) (3) VENTILATION. b. Bathrooms, laundry rooms, water closet compartments and similar rooms shall be provided with natural ventilation by means of openable exterior openings with an area not less than 1 ½ square feet. A mechanical ventilation system connected directly to the outside may be provided in lieu of these required exterior openings for natural ventilation in bathrooms that contain a bathtub, shower or combination thereof; laundry rooms; and similar rooms. Such a system must be capable of providing 5 air changes at the rate of 50 cubic feet per minute if the system operation is intermittent; or 20 cubic feet per minute if the operation is constant. The point of discharge of exhaust air shall be at least 3 feet from any opening into the building. In bathrooms containing only a water closet, lavatory or combination thereof; or in similar rooms, ventilation may be provided with an approved mechanical recirculating fan or a similar device designed to remove odors from the room. |
| 06/20/2018 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 06/20/2018 | T.C. Ch. 16, Sec. 16-11(h) INTERIOR INSECT AND RODENT CONTROL. The interior of all buildings and structures shall be kept free from infestation of insects, rodents and other noxious pests where such infestation threatens the health, safety or welfare of a person or persons. |
| 06/20/2018 | T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism. |
| 06/20/2018 | T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness. |
| 06/20/2018 | T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly. |
Outstanding Inspections
Case Number: T18DV03371
Case Status: COMPLIAN
Case Description: RES: MINIMUM HOUSING
Total Outstanding Inspections - 8
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected | ||
| NPO(EL)-MAIN/PANEL/SUB/DISCONT | None | Not Inspected | ||
| NPO(EL)-WIRING/SWITCH/OUTLT/FX | None | Not Inspected | ||
| NPO(HC)-COOLING | None | Not Inspected | ||
| NPO(HC)-NO VENTILATION | None | Not Inspected | ||
| NPO - INSECTS/PESTS | None | Not Inspected | ||
| NPO - SMOKE ALARMS | None | Not Inspected | ||
| NPO - INT. BUILDING MAINTENANC | None | Not Inspected |
Completed Inspections
Case Status: COMPLIAN
Case Number: T18DV03371
Case Description: RES: MINIMUM HOUSING
Total Completed Inspections - 1
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 06/20/2018 | INSP - INITIAL CODE ENFORCMENT | MENDOZA | Approved | INOPERABLE WINDOW IN THE MAIN BEDROOM WINDOW LOCATED IN THE BATHROOM IS BROKEN. FRAMING IS DETERIORATED AND RUSTED INOPERABLE WINDOW IN THE LIVING ROOM DINING ROOM WINOW SCREEN IS NOT PROPERLY SECURED FRONT DOOR DOES NOT SEAL PROPERLY ELECTRICAL CIRCUIT FOR THE STOVE IS NOT SECURED AND NOT PROTECTED FROM DAMAGE KITCHEN STOVE FAN IS INOPERABLE HALL LIGHT IS INOPERABLE SMOKE DETECTOR IN INOPERABLE INPROPER ELECTRICAL RUN IN THE APPLIANCE ROOM, NOT SECURED TO THE WALL, EXCESS CONDUIT IS HANGING REAR DOOR DOES NOT SHUT PROPERLY. FRAMING AROUND THE REAR DOOR IS DETERIORATED AND NOT PROPERLY SEALED REAR DOOR LIGHT FIXTURE IS INOPERABLE COOLER IS EXTREMELY DETERIORATED WITH EXCESSIVE RUST AND CALCIUM BUILD UP. ELECTRICAL PANELS DETERIORATED AND HAVE EXCESSIVE RUST INSUFFICIENT SIZE OF SHUT OFF BREAKER FOR 4652 MISSING PUNCH OUTS ON PANEL AND DEAD FRONT. ON PANEL MISSING A DEAD FRONT GROUND IS BROKEN FROM THE WATER PIPING. NO EVIDENCE OF GROUNDING RODS UNSECURED CONDUIT COMING FROM THE PANELS PANELS LACK ALL LABELING UNKNOW BREAKERS IN THE PANELS |
Completed Activity Special Conditions
Case Description - RES: MINIMUM HOUSING
Case Number - T18DV03371
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
| Date | Name |
| 06/20/2018 | CONTACTED BY PHONE |
| 06/20/2018 | CONTACTED IN PERSON |
| 06/20/2018 | CONTACTED BY MAILING |
| 09/11/2018 | CONTACTED BY EMAIL |
| 06/20/2018 | NOTICE OF VIOLATION ISSUED |
| 09/11/2018 | VIOLATION CLOSED |