Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you cannot find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES
Address:

Entered Date:

11/01/2017

Applicant:

BUDINGER PHILIP M

Description:

T.P.D. CALLED WITH HAZARDOUS ELECTRICAL AND LIVING CONDITION

Case Violations

Case Number: T17DV05718
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 1
Violation Date Code Statue
11/28/2017 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV05718
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
11/21/2017 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EXTERIOR INSPECTION: THERE ARE TWO MAIN DISCONNECTS ON THE BUILDING. THE 30 AMP IS FOR THE 607 W SIMMONS RD ADDRESS WHICH IS OCCUPIED, THE OTHER DISCONNECT IS FOR THE BOAT HOUSE AND THE 611 ADDRESS CURRENTLY A VACANT BUILDING. THE MAIN DISCONNECT FOR THE 607 W SIMMONS RD HAS ONE NON METALLIC SHEATHED CABLE PROVIDING POWER TO THE HOME. THE INSTALL OF THE CABLE IS AN UNAPPROVED WIRING METHOD. THERE IS NO GROUNDING SYSTEM. THERE ARE UNUSED OPENINGS ON THE EQUIPMENT. UNIT 611 W SIMMONS RD HAS AN INTERIOR PANEL WITH 4 CIRCUIT BREAKER. THIS IS NEW EQUIPMENT. THERE ARE MULTIPLE WALL OUTLET WITH DAMAGED, BURNT RECEPTACLES. THE BUILDING HAS NO MAIN DISCONNECT. NO GROUNDING SYSTEM. THERE ARE ELECTRICAL CODE VIOLATIONS WITH THE OUTDOOR ELECTRICAL EQUIPMENT.
01/04/2018 INSP - FOLLOW UP CODE ENFORCE VALDEZ Approved PERMIT ISSUED T17CM09572 12-29-2017, CLOSE CASE

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T17DV05718
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 6
Date Name
11/06/2017 CONTACTED BY PHONE
11/28/2017 CONTACTED IN PERSON
12/06/2017 CONTACTED BY MAILING
11/06/2017 NOTICE OF VIOLATION ISSUED
11/06/2017 RESEARCH
11/06/2017 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws.