Case: T17DV04569
Case Details
Entered Date:
09/14/2017
Applicant:
SMSJ TUCSON HOLDINGS LLC
Description:
COMMUNICATION CALLED THAT T.F.D. ON SITE WITH A BUILDING FIRE
Outstanding Inspections
Case Number: T17DV04569
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 7
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
INSP - FOLLOW UP CODE ENFORCE | None | Not Inspected | ||
09/14/2017 | EMERGENCY CALL OUT | VIDAL | Item closed | |
09/14/2017 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | VIDAL | Item closed | |
09/14/2017 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VIDAL | Item closed | |
09/14/2017 | NPO - SMOKE ALARMS | VIDAL | Item closed | |
09/14/2017 | NPO - OTHER | VIDAL | Item closed | |
09/14/2017 | NPO - INT. BUILDING MAINTENANC | VIDAL | Item closed |
Completed Inspections
Case Status: COMPLIAN
Case Number: T17DV04569
Case Description: EMERGENCY
Total Completed Inspections - 1
End Date | Description | Inspector | Results | Comments |
---|---|---|---|---|
09/14/2017 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | Supervisor Martin Romero called that T.F.D. on site with a building fire. Arrived and the units still on site and had a fire on the 3rd floor in a light fixture and no damage to the building or the wiring in the wall. The light fixture was a total lost and will be replaced and will need to order a new fixture. Could take 4 to 6 weeks to get the light fixture. Has light smoke damage to the walls and the ceiling tiles in the hallway only. The rooms on the 3rd floor have no damage. The sprinkler head did not go off and the fire had an extinguisher used to put the fire out by one of the doctors on site. The electrical contractor was on site and had the light fixture removed from the wall and the fire investigators were checking for the cause of the fire. The breaker was turned off during the fire and was back on once the fixture was removed and the wiring in the wall was checked OK. The maintenance was cleaning the area and the offices in the area will remain opened. At this time the case will be closed due to replacing the light fixtures is a maintenace item and will not require a permit or inspection. The light fixture is being check for any recalls due to had trouble with 3 other light fixtures in the building. Violation Abated, Close Case. RV. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T17DV04569
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date | Name |
09/14/2017 | VIOLATION CLOSED |