Case Details

Status:

COMPLIAN

Type:

EMERGENCY
Address:

Entered Date:

09/01/2017

Applicant:

DAMIEN CHOI & JENNIFER E MATIAS CP/RS

Description:

TRANSIENT LIVING WITHOUT POWER/ PER TPD

Outstanding Inspections

Case Number: T17DV04190
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 7
End Date Description Inspector Results Comments
INSP - FOLLOW UP CODE ENFORCE None Not Inspected
09/01/2017 EMERGENCY CALL OUT VALDEZ Item initialized
09/01/2017 NPO - UNSECURED BUILD OR STRUC VALDEZ Item initialized
09/01/2017 NPO(EL)-MAIN/PANEL/SUB/DISCONT VALDEZ Item initialized
09/01/2017 NPO(EL)-WIRING/SWITCH/OUTLT/FX VALDEZ Item initialized
09/01/2017 NPO(DL)-DILAPIDATED STRUCTURE REED Item initialized
09/01/2017 NPO(DL)-DILAPIDATED STRUCTURE VALDEZ Item initialized

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV04190
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
09/01/2017 INSP - INITIAL CODE ENFORCMENT GONZALEZ Approved ON SITE INSPECTION TPD EVENT NUMBER 1709010169 OFFICER GONZALES
09/01/2017 INSP - INITIAL CODE ENFORCMENT VALDEZ Approved EMERGENCY CALL OUT BY TPD: TRANSIENT LIVING WITH OUT POWER IN THE FRONT SHED AND UNITS 1 AND 2. MAIN DISCONNECTS HAVE MULTIPLE CODE VIOLATIONS, TEP WAS CALLED OUT DUE TO TAMPERING WITH THE ELECTRICAL SYSTEM. TEP DID REMOVE METER FROM UNIT 1 AND WAS UNABLE TO PULL METER OFF CENTER PANEL LABELED UNIT 2 DUE TO TAMPERING, FEEDERS WERE CUT OFF AT THE SERVICE DROP. PANEL LABELED UNIT 3 HAS CONDUCT OPEN AND CUT EXPOSED CONDUCTORS.. THE ENTIRE SERVICE HAS NO GROUNDING ELECTRODE SYSTEM AND UNUSED OPENINGS. SEVERE TAMPERING WITH UNITS 1 DOWN STREAM PANELS MISSING CONDUCTORS TO THE UNIT, FEEDERS EXPOSED AND DISCONNECTED, USED OPENINGS. INTERIOR DAMAGE TO UNIT 1 DRYWALL CEILINGS AND WALLS, MISSING HARDWARE DOOR LOCKS TO TWO EXIT DOORS. BEDROLLS AND FOOD CONTAINERS IN EVERY ROOM, UN DISPOSED FECES IN BATHROOM. UNIT 2 TENANTS HAD A GENERATOR WITH EXTENSION CORDS, TENANTS STATED THEY DO USE THE GENERATOR TO BACK FEED THE UNIT. THE INTERIOR HAS MULTIPLE EXTENSION CORDS BEING USED FROM THE GENERATOR. UNITS 1, 2 AND THE SHED WERE SECURED BY PINNING OR SCREWING AND BOARDING. ALL ABOVE UNITS AND THE SHED WAS CONDEMNED. PLACARDS POSTED,, CLOSE CASE

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T17DV04190
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 7
Date Name
09/01/2017 CONTACTED BY PHONE
09/01/2017 CONTACTED IN PERSON
09/01/2017 CONTACTED BY EMAIL
09/01/2017 NOTICE AND ORDER ISSUED
09/01/2017 VIOLATION CLOSED
09/01/2017 STRUCTURE SECURED BY ???
09/01/2017 8-5 CITY COMM EMERGENCY

Documents

File Name Document Type  
150 W LINCOLN ST NOTICE AND ORDER.PDF DOCUMENTS VIEW
20170901_100311.JPG DOCUMENTS VIEW
20170901_102519.JPG DOCUMENTS VIEW
20170901_102525.JPG DOCUMENTS VIEW
20170901_102538.JPG DOCUMENTS VIEW
20170901_102730.JPG DOCUMENTS VIEW
20170901_104350.JPG DOCUMENTS VIEW
20170901_104352.JPG DOCUMENTS VIEW
20170901_104358.JPG DOCUMENTS VIEW
20170901_104404.JPG DOCUMENTS VIEW
20170901_104419.JPG DOCUMENTS VIEW
20170901_104426.JPG DOCUMENTS VIEW
20170901_104440.JPG DOCUMENTS VIEW
20170901_104744.JPG DOCUMENTS VIEW
20170901_104757.JPG DOCUMENTS VIEW
20170901_104801.JPG DOCUMENTS VIEW
20170901_104822.JPG DOCUMENTS VIEW
20170901_105023.JPG DOCUMENTS VIEW
20170901_112350.JPG DOCUMENTS VIEW
20170901_112354.JPG DOCUMENTS VIEW
20170901_120449.JPG DOCUMENTS VIEW
20170901_120512.JPG DOCUMENTS VIEW
20170901_120652.JPG DOCUMENTS VIEW
20170901_120653.JPG DOCUMENTS VIEW