Case: T17DV04088
Case Details
Entered Date:
08/29/2017
Applicant:
FRONTIER MOTEL LLC
Description:
STRUCTURAL DAMAGE TO THE ROOF DUE WIND. WORK WITHOU PERMITS
Case Violations
Case Number: T17DV04088
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Violations: 5
| Violation Date | Code Statue |
|---|---|
| 09/25/2017 | T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe. |
| 09/25/2017 | T.C. Ch. 16, Sec. 16-11(a)(3) Every existing dwelling unit shall be provided with smoke detectors in good operating condition as required by the Tucson Fire Code of the City of Tucson. |
| 09/25/2017 | T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (1) All dwellings and dwelling units shall be provided with electrical service. Electrical facilities connected to or in any building or structure are to be maintained hazard-free and in a state of good repair. The electrical system shall be free from such hazards as bare wiring; overloaded circuits or services; equipment not properly grounded; over-fused circuits; misuse of wiring, including the use of extension cords in lieu of permanent wiring; non-approved wiring; and wiring exposed to moisture or extreme heat. Broken, loose, frayed, inoperable, defective or missing portions of the electrical service, lines, switches, outlets, fixtures and fixture coverings shall be repaired or replaced. (2) All electrical equipment, wiring and appliances shall be installed and maintained in a safe manner and in accordance with all applicable laws. |
| 09/25/2017 | T.C. Ch. 16, Sec. 16-12(b)(3) ROOFS. The roof of every building or structure shall be maintained in a safe condition and shall provide weather protection for that building or structure. Roof coverings shall not be rotted, broken, split, buckled or otherwise deteriorated. T.C. Ch. 16, Sec. 16-12(b) FOUNDATIONS, WALLS, ROOFS, AND CHIMNEYS. Every foundation, wall, roof, chimney and all exterior surfaces of buildings and structures shall be maintained in structurally sound condition and shall provide weather protection. All wood showing evidence of termite damage or decay, where structural or functional integrity is impaired, shall be replaced. |
| 09/25/2017 | T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition. |
Outstanding Inspections
Case Number: T17DV04088
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 8
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 09/25/2017 | EMERGENCY CALL OUT | VIDAL | Notice of violation | |
| 09/25/2017 | NPO(EL)-MAIN/PANEL/SUB/DISCONT | VIDAL | Notice of violation | |
| 09/25/2017 | NPO(EL)-WIRING/SWITCH/OUTLT/FX | VIDAL | Notice of violation | |
| 09/25/2017 | NPO(PL)-WATER HEATERS | VIDAL | Notice of violation | |
| 09/25/2017 | NPO(HC)-HEATING & VENTILATION | VIDAL | Notice of violation | |
| 09/25/2017 | NPO - SMOKE ALARMS | VIDAL | Notice of violation | |
| 09/25/2017 | NPO - OTHER | VIDAL | Notice of violation | |
| 09/25/2017 | NPO - WORK WITHOUT PERMIT | VIDAL | Notice of violation |
Completed Inspections
Case Status: COMPLIAN
Case Number: T17DV04088
Case Description: EMERGENCY
Total Completed Inspections - 2
| End Date | Description | Inspector | Results | Comments |
|---|---|---|---|---|
| 08/29/2017 | INSP - INITIAL CODE ENFORCMENT | VIDAL | Approved | Office called and has T.P.D. on site with a blown off roof and work being done with out permits. Arrived and did find where the roof covering has blown off the roof and the repairs have been done and covered with a tarp. There is electrical that has been damaged and has wire nuts on the wires that are exposed. Some of the conduits are bent and not secured property and have wires holding the conduit from falling. Did walk the property and found where the main electrical service has been tripled lugged. Found where some the beam supports are rotted and not bearing properly and have temporary supports added to hole the beam supports on porches and the buildings. Did talk to the manager and the owners and the contractor did show to go over on what needs to be done on the entire property. They do have an architect already working on the drawings and waiting for the money to start the work and get the permit. Everything that was discussed has been placed on the plans to have approval. Will do N.O.V. RV. |
| 02/13/2018 | INSP - FOLLOW UP CODE ENFORCE | VIDAL | Approved | The permits T17CM09366 and T17CM09367 have been issued on 12-20-17 and at this time the case will be closed. Violation Abated, Close Case. RV. |
Completed Activity Special Conditions
Case Description - EMERGENCY
Case Number - T17DV04088
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 2
| Date | Name |
| 09/26/2017 | CONTACTED BY MAILING |
| 08/30/2017 | NOTICE OF VIOLATION ISSUED |