Microfiche records prior to 2006 have not been completely digitized and may not be available yet on PRO. If you can not find what you are looking for please submit a records request.

Case Details

Status:

COMPLIAN

Type:

EMERGENCY

Entered Date:

08/15/2017

Applicant:

NHC-AZ101 LLC

Description:

SINK HOLE ON PROPERTY

Outstanding Inspections

Case Number: T17DV03684
Case Status: COMPLIAN
Case Description: EMERGENCY
Total Outstanding Inspections - 5
End Date Description Inspector Results Comments
08/21/2017 EMERGENCY CALL OUT VIDAL Item closed
08/21/2017 NPO(PL)-PLUMBING SYSTEM & FX VIDAL Item closed
08/21/2017 NPO - OTHER VIDAL Item closed
08/21/2017 NPO - EXT. BUILDING MAINTENANC VIDAL Item closed
08/21/2017 NPO - WORK WITHOUT PERMIT VIDAL Item closed

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV03684
Case Description: EMERGENCY
Total Completed Inspections - 2
End Date Description Inspector Results Comments
08/15/2017 INSP - INITIAL CODE ENFORCMENT VIDAL Approved The supervisor called and T.F.D. on site with a sink hole. Arrived and the fire units have cleared the site and a plumber was on site including the maintenance crew for the mobile home park. Did find a 2' x 3' hole and was approx 5' deep. The hole goes underground approx. 40 l.f. approx. 4' wide where a metal culvert has deteriorated at the top section and the sides are caving into the culvert area. Not able to see the damage due to the dirt has not fallen to expose the culvert. Has an entrance point approx. 100' to the east and cover with dirt and not able to get a visual on the damage of the culvert pipe. The culvert goes approx. 350 l.f. to the west of the hole and again not able to see the damage of the culvert pipe or where it exit. RAM Plumbing was on site and was looking and called an engineer to come and check the damage and check on doing the drawings for the permit that is going to be required to have the repairs and relacement done. The plumbing contractor was bringing a camera to place in the culvert to check the damage from the entrance of the culvert. Will call on the results of the camera. Did get permission to install a fence over the culvert area and blocked one driveway to space #40 and went to space #39 to the side of the mobile home. Space #41 is a vacant lot and the area was fenced off to the driveway and than went into the street area to allow for a backhoe to dig and place the dirt pile when The manager gave permission due to not able to get anyone to come today. Did talk to Martin Romero the supervisor to give the update of the fence and the plumber on site. The manager signed the paperwork and once the digging starts and have a better update of the trench, the tenants will be allowed to remain in the mobile homes at this time and will be evaluated at the time of digging. The engineer did show to the property and did look at the damage and the pipe at the entrance and tried to find the exit in a wash area and was not able to fine the exit. Did go over the permits and the inspection may require special inspection due to what the culvert id for a drainage system. Will check in 5 days. RV.
08/21/2017 INSP - FOLLOW UP CODE ENFORCE VIDAL Approved The work is done and needs to continue under the mobile home #39 due to the culvert pipe is failing. At this time the case will be closed. Violation Abated, Close Case. RV.

Completed Activity Special Conditions

Case Description - EMERGENCY
Case Number - T17DV03684
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 4
Date Name
08/16/2017 NOTICE OF VIOLATION ISSUED
08/21/2017 VIOLATION CLOSED
07/17/2018 SEC LETTER OF BILLING FOR $??? SENT TO OWNERS
08/16/2017 STRUCTURE SECURED BY ???