Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

06/27/2017

Applicant:

ANN M BOYCE

Description:

BUILDING CODE VIOLATIONS

Case Violations

Case Number: T17DV02799
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 5
Violation Date Code Statue
06/29/2017 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
06/29/2017 T.C. Ch. 16, Sec. 16-14(c) BUILDINGS AND STRUCTURES CONSTITUTING A NUISANCE. All buildings and structures are to be maintained so as not to pose a threat to the health and safety of any person or persons. The condition of a building or structure that meets any or all of the following is a public nuisance, is a violation of this chapter, and subjects the building or structure to abatement as provided in Article VI of this chapter, including demolition as provided in section 16-65: (1) The building or structure lacks safe and adequate means of exit in case of fire or panic.
06/29/2017 T.C. Ch. 16, Sec. 16-11(c) ELECTRICAL SYSTEM. (3) Every habitable room must have at least two electrical receptacle outlets, or one outlet and one electric light fixture. Every bathroom, water closet compartment, and laundry room must have at least one electric light fixture.
06/29/2017 T.C. Ch. 16, Sec. 16-11(j) ACCESS CONTROL. (1) Exterior doors, including sliding glass doors, must have an operable locking mechanism. Double cylinder dead bolt locks or other mechanisms that prevent rapid egress in case of fire or other emergency are prohibited. (2) All windows must have an operable locking mechanism.
09/14/2017 NOTICE OF VIOLATION ISSUED

Outstanding Inspections

Case Number: T17DV02799
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
09/13/2017 NPO - UNSECURED BUILD OR STRUC BIGMAN Follow-up inspection
09/13/2017 NPO(DL)-DILAPIDATED STRUCTURE BIGMAN Follow-up inspection
09/13/2017 NPO - EXT. BUILDING MAINTENANC BIGMAN Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV02799
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/29/2017 INSP - INITIAL CODE ENFORCMENT BIGMAN Approved BUILDING 6 6204 O 6203 V 6102 O 6101 O "Pocket around the beam pocket has a large space "Decking next to unit 6204 wood is deteriorated. Support beam is rotting underneath "Beam pocket next to unit #6102 has a large space/opening around the beam "Steps leading up to the top deck metal rusted on 2nd step and poking out " Railing loose on the west side of unit 6203 "Railing has loose screws on west side next to unit 6204 6203 - Door is missing hardware/unit is vacant 6203 - Water leak on the roof into the interior vacant unit 6204 & 6203 Outdoor lighting partially removed. Facia on the roofing has water damage on the west side of the bldg..
09/13/2017 INSP - FOLLOW UP CODE ENFORCE BIGMAN Approved OWNER OBTAINED PERMIT FOR THE REPAIR TO THE BALCONIES #T17CM02799.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T17DV02799
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
06/29/2017 CONTACTED BY MAILING