Case Details

Status:

COMPLIAN

Type:

MULTIPLE TYPES

Entered Date:

06/27/2017

Applicant:

ANN M BOYCE

Description:

BUILDING CODE VIOLATIONS

Case Violations

Case Number: T17DV02797
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Violations: 7
Violation Date Code Statue
06/28/2017 T.C. Ch. 16, Sec. 16-12(a)(2) PROTECTIVE TREATMENT. All exterior wood surfaces, except for decay-resistant woods, must be protected from deterioration and from the elements by paint or other protective treatment or covering. Any exterior wood surface that has paint that is peeling, flaking, cracked, blistered or chipped, resulting in bare, unprotected surfaces, the deteriorated condition of that surface must be eliminated and the surface repainted. All metal surfaces subject to corrosion or rust must be treated or coated to inhibit corrosion and rust, unless corrosion or rust is a design element.
06/28/2017 T.C. Ch. 16, Sec. 16-12(a) EXTERIOR SURFACES. (1) Weather protection. All weather-exposed exterior surfaces of every building, including windows and doors, shall provide weather protection. Every building shall be weather protected to provide shelter for the occupants against the elements and to exclude moisture and dampness.
06/28/2017 T.C. Ch. 16, Sec. 16-4. PERMITS REQUIRED. Unless otherwise exempt pursuant to section 301 of the Administrative Code, as adopted by reference per section 6-1 of this Code, or pursuant to any other ordinance or statute, no building, structure or building service equipment regulated by this chapter or by the technical codes adopted by the city shall be built, erected, constructed, enlarged, altered, repaired, moved, improved, removed, converted or demolished unless a permit first has been obtained from the building official in the manner provided in the administrative and building codes adopted by the city. The purpose of a permit is to ensure that all construction is inspected by qualified City of Tucson personnel as directed by ordinance to verify compliance with city codes. Failure to obtain proper permit with inspections and approvals shall deem the construction to be unsafe.
06/28/2017 T.C. Ch. 16, Sec. 16-12(a) (4) WINDOWS, SKYLIGHTS, AND DOORS. Every window, skylight, door and all associated frames, shall be kept in sound condition, repair and weather tight. All glazing materials shall be maintained free from cracks and holes. Every window, other than a fixed window, shall be easy to open and capable of being held in position by window hardware. All window and door hardware shall be maintained in good condition and shall function properly.
06/28/2017 T.C. Ch. 16, Sec. 16-12(a)(3) BOARDED WINDOW OR DOOR OPENINGS. a. No occupied structure may have boarded window or door openings, except as necessary on a temporary basis to keep the structure secure while under repair. b. While vacant structures may temporarily be secured by boarding up window and door openings in accordance with section 16-14(b), having or maintaining boarded window or door openings on a vacant structure for 180 days or more in any one-year period is prohibited.
06/28/2017 T.C. Ch. 16, Sec. 16-13(b) ACCUMULATION OF REFUSE PROHIBITED. Each owner, lessee, tenant, resident or occupant shall maintain a property so it is free of accumulated refuse and debris. Accumulated refuse and debris means contained or uncontained refuse and debris that is present on the property in a manner not authorized by the Tucson Code. Material recycling facilities meeting the requirements of section 15-24.7 are exempt from this prohibition.
09/14/2017 NOTICE OF VIOLATION ISSUED

Outstanding Inspections

Case Number: T17DV02797
Case Status: COMPLIAN
Case Description: MULTIPLE TYPES
Total Outstanding Inspections - 3
End Date Description Inspector Results Comments
09/13/2017 NPO(DL)-DILAPIDATED STRUCTURE BIGMAN Follow-up inspection
09/13/2017 NPO - EXT. BUILDING MAINTENANC BIGMAN Follow-up inspection
09/13/2017 NPO - WORK WITHOUT PERMIT BIGMAN Follow-up inspection

Completed Inspections

Case Status: COMPLIAN
Case Number: T17DV02797
Case Description: MULTIPLE TYPES
Total Completed Inspections - 2
End Date Description Inspector Results Comments
06/21/2017 INSP - INITIAL CODE ENFORCMENT BIGMAN Approved BLDG 1 - UPSTAIRS UNITS VACANT. DECKING: RAILING IS LOOSE ON THE EAST AND WEST SIDE OF THE BLDG., DECKING MEMBERS ARE ROTTED, DECKING STRUCTURE HAS MISSING HARDWARE. 1212 - OCCUPIED.
09/13/2017 INSP - FOLLOW UP CODE ENFORCE BIGMAN Approved OWNER OBTAINED PERMITS FOR THE REPAIRS TO BUILDING 1 DECKING #T17CM05696.

Completed Activity Special Conditions

Case Description - MULTIPLE TYPES
Case Number - T17DV02797
Case Status: COMPLIAN
Total Completed Case Activity Conditions: 1
Date Name
06/28/2017 CONTACTED BY MAILING